نتایج جستجو برای: montanide

تعداد نتایج: 327  

2004
S. S. Tsygankov A. A. Lutovinov S. A. Grebenev M. R. Gilfanov R. A. Sunyaev

The variability of the X-ray flux from the pulsar GX 301-2 is analyzed by using data from the ART-P telescope of the Granat Observatory. The intensity variations with time scales of several thousand seconds are studied at various orbital phases. The high-state flux from the source exceeds its low-state flux by as much as a factor of 10. The hardness and spectrum of the source are shown to chang...

2008
Lutovinov Alexander

Recent results of the spectral and timing analysis of X-ray pulsars in hard X-rays with the INTEGRAL observatory are reviewed. The evolution of the cyclotron line energy with the source luminosity was studied in detail for the first time for several sources. It was shown that for V0332+53 this dependence is linear, but for 4U0115+63 and A0535+262 it is more complicated. There are some evidences...

Journal: :Vaccine 2006
Sanjay Ahuja Fredrik Pettersson Kirsten Moll Cathrine Jonsson Mats Wahlgren Qijun Chen

The interactions of Plasmodium falciparum infected erythrocytes parasitized red blood cells (pRBC) with endothelial receptors and erythrocytes are mediated by multiple Duffy-binding like (DBL) and cysteine-rich interdomain region (CIDR) domains harboured in the Plasmodium falciparum erythrocyte membrane protein 1 (PfEMP1). The success of a subunit vaccine based on PfEMP1 depends on its ability ...

2010
Elke S Bergmann-Leitner Ryan M. Mease Patricia De La Vega Tatyana Savranskaya Mark Polhemus Christian Ockenhouse Evelina Angov

BACKGROUND The Plasmodium protein Cell-traversal protein for ookinetes and sporozoites (CelTOS) plays an important role in cell traversal of host cells in both, mosquito and vertebrates, and is required for successful malaria infections. CelTOS is highly conserved among the Plasmodium species, suggesting an important functional role across all species. Therefore, targeting the immune response t...

2004
S. S. Tsygankov A. A. Lutovinov S. A. Grebenev M. R. Gilfanov R. A. Sunyaev

The variability of the X-ray flux from the pulsar GX 301-2 is analyzed by using data from the ART-P telescope of the Granat Observatory. The intensity variations with time scales of several thousand seconds are studied at various orbital phases. The high-state flux from the source exceeds its low-state flux by as much as a factor of 10. The hardness and spectrum of the source are shown to chang...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید