نتایج جستجو برای: optical imaging system

تعداد نتایج: 2807792  

Journal: :Optics express 2005
B Vakoc S Yun J de Boer G Tearney B Bouma

Phase-resolved Doppler optical coherence tomography has been used to image blood flow dynamics in various tissues using both time-domain and spectral-domain optical coherence tomography techniques. In this manuscript, we present phase-resolved Doppler imaging with a high-speed optical frequency domain imaging system. We demonstrate that by correcting for spurious timing-induced phase errors, ex...

2017
Eunjoo Choi Masato Ohmi Takayuki Komatsu Shogo Yagi Kazuo Fujiura

We have developed optical coherence tomography system with KTN optical probe for a diagnosis in the orthopedic surgery fields. The present system demonstrates that biological image was measured by using KTN optical scanner for having degree of freedom in sample arm as optical coherence tomography. In addition, the developed optical coherence tomography (OCT) system has shown feasibility for ima...

Journal: :Journal of the Optical Society of America. A, Optics, image science, and vision 2012
Xue-Feng Liu Xu-Ri Yao Xi-Hao Chen Ling-An Wu Guang-Jie Zhai

We report an experimental demonstration of optical coherence tomography for transmissive objects utilizing second-order correlation ghost imaging with thermal light. To evaluate the longitudinal resolution of our system, the concept of the imaging longitudinal coherence length is introduced, which is more accurate for judging the image quality of ghost imaging with unequal optical paths than th...

Journal: :Applied optics 1998
H B Wach E R Dowski W T Cathey

Control of chromatic aberration through purely optical means is well known. We present a novel, to our knowledge, optical-digital method of controlling chromatic aberration. The optical-digital system, which incorporates a cubic phase-modulation (CPM) plate in the optical system and postprocessing of the detected image, effectively reduces a system's sensitivity to misfocus in general or axial ...

Journal: :Optics letters 1996
G J Tearney B E Bouma S A Boppart B Golubovic E A Swanson J G Fujimoto

The development of techniques for high-speed image acquisition in optical coherence tomography (OCT) systems is essential for suppressing motion artifacts when one is imaging living systems. We describe a new OCT system for performing micrometer-scale, cross-sectional optical imaging at four images/s. To achieve OCT image-acquisition times of less than 1 s, we use a piezoelectric fiber stretche...

2011
Matthias Rieckher Udo Jochen Birk Heiko Meyer Jorge Ripoll Nektarios Tavernarakis

We describe a versatile optical projection tomography system for rapid three-dimensional imaging of microscopic specimens in vivo. Our tomographic setup eliminates the in xy and z strongly asymmetric resolution, resulting from optical sectioning in conventional confocal microscopy. It allows for robust, high resolution fluorescence as well as absorption imaging of live transparent invertebrate ...

Journal: :Applied optics 2017
Fengqiang Li Joshua Yablon Andreas Velten Mohit Gupta Oliver Cossairt

Lasers and laser diodes are widely used as illumination sources for optical imaging techniques. Time-of-flight (ToF) cameras with laser diodes and range imaging based on optical interferometry systems using lasers are among these techniques, with various applications in fields such as metrology and machine vision. ToF cameras can have imaging ranges of several meters, but offer only centimeter-...

Journal: :Journal of the Optical Society of America. A, Optics, image science, and vision 2007
Samuel T Thurman James R Fienup

Fizeau Fourier transform imaging spectroscopy (FTIS) is a technique for collecting both spatial and spectral information about an object with a Fizeau imaging interferometer and postprocessing. The technique possesses unconventional imaging properties due to the fact that the system transfer functions, including the imaging and spectral postprocessing operations, are given by cross correlations...

Journal: :Optics letters 2013
Wenxin Xing Lidai Wang Konstantin Maslov Lihong V Wang

Photoacoustic microscopy (PAM), whose spatial resolution and maximum imaging depth are both scalable, has made great progress in recent years. However, each PAM system currently achieves only one resolution with an associated maximum imaging depth. Here, we present an integrated optical-resolution (OR) and acoustic-resolution (AR) PAM system implemented by delivering light via an optical fiber ...

Journal: :Journal of biomedical optics 2002
Andrew M Rollins Siavash Yazdanfar Jennifer K Barton Joseph A Izatt

Color Doppler optical coherence tomography (CDOCT) is a functional extension of optical coherence tomography (OCT) that can image flow in turbid media. We have developed a CDOCT system capable of imaging flow in real time. Doppler processing of the analog signal is accomplished in hardware in the time domain using a novel autocorrelation technique. This Doppler processing method is compatible w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید