نتایج جستجو برای: potentiometry ion selective membrane electrode

تعداد نتایج: 802881  

Journal: :physical chemistry and electrochemistry 0

2-amino-n-benzthioazolyl benzamide (abtb) was synthesized, characterized and used for thefabrication of a potentiometric sensor for cu2+ metal ions. the electrode exhibits linear response to cu(ii) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 m) with nernstian slope of 30 ± 1.5 mvper decade. the electrode can be used in the ph range from 2 to 9. it has a fast response time of about1...

2004

A theory for the interpretation of the operation mechanism of ion-selective membrane electrodes is briefly outlined. The statements are based on the accumulated results concerning the electrochemical and spectrochemical behaviour of ion-selective membranes.

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم 1390

a novel silver (ag) nanocomposite electrode was proposed that fabricated from metal nanostructures and ionic liquids. the combined application of unique properties of nanomaterials and ionic liquids in the design of this ag nanocomposite results in electrodes with interesting advantages compared to the conventional metal disk electrode. in the first part of this thesis, the elecrocatalytic eff...

Journal: :Bulletin of the Chemical Society of Japan 1971

2011
M. Soledad García Joaquín A. Ortuño María Cuartero Mustafa Salem Abuherba

The construction and characterization of a new ion-selective electrode for the determination of the antipsychotic ziprasidone in mixed solvents is presented. The electrode contains a plasticized polymeric membrane based on a ziprasidone-tetraphenylborate ion-exchanger. The influence of membrane composition on the electrode response towards ziprasidone in hydroalcoholic solutions was studied. Th...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Demet Kuruoğlu Esin Canel Shahabuddin Memon Mustafa Yilmaz Esma Kiliç

A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2-11.5 pH range with a slope of 54.0 +/- 0.2 mV/pH at 20 +/- degrees C. This electrode showed a rapid response of the emf to changes in the pH, high ion selec...

Arezoo Ghaemi, Zahra Setareh

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

2009
Svetlana V. Lamaka Maryna G. Taryba Mikhail L. Zheludkevich Mario G. S. Ferreira

The design and properties of novel type of solid-contact ionophore-based ion-selective microelectrodes are reported. The microelectrode is based on an insulated needle-shaped metallic wire with an exposed apex. The ion-to-electron transducer is made of poly(3-octylthiophene-2,5-diyl) and placed between an ion-selective membrane and the metallic tip. The ion-selective polyvinyl chloride-based me...

Journal: :Electrochimica Acta 2022

Calibration-free coulometric determination of K+ ions was realized using an all-solid-state thin-layer laminated cell with a simple laminate structure. The fabricated consists Ag/AgCl electrode, plastic spacer for positioning the aqueous sample solution, organic ion-selective membrane, and conducting polymer/carbon electrode. An originally prepared conducting-polymer-dispersed ink cast on condu...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید