نتایج جستجو برای: saturation current

تعداد نتایج: 822328  

2002
A. R. Kerr

In ALMA Memo 321, Plambeck points out that saturation (gain compression) is likely to be a significant factor limiting the calibration accuracy of ALMA observations. In this memo, saturation by broadband noise and CW signals is analyzed for representative SIS receivers operating at different frequencies. Many SIS mixers in current use are expected to exhibit a significant degree of gain compres...

1994
Ganesh Samudra Alan Yong Teng Kiat Lee

Exact analytical expressions for the switching delay of an inverter driving an RC load, taking into account the velocity saturation, are obtained. Modified expressions to include theeffectofsource resistance arethen presented.Owing to the limitation on switching current imposed by the velocity saturation mechanism, the switching delay is substantially increased for identical width-io-length rat...

Journal: :The Journal of General Physiology 1992
X G Zong M Dugas P Honerjäger

Veratridine modification of Na current was examined in single dissociated ventricular myocytes from late-fetal rats. Extracellularly applied veratridine reduced peak Na current and induced a noninactivating current during the depolarizing pulse and an inward tail current that decayed exponentially (tau = 226 ms) after repolarization. The effect was quantitated as tail current amplitude, Itail (...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه ارومیه 1377

the methods which are used to analyze microstrip antennas, are divited into three categories: empirical methods, semi-empirical methods and full-wave analysis. empirical and semi-empirical methods are generally based on some fundamental simplifying assumptions about quality of surface current distribution and substrate thickness. thses simplificatioms cause low accuracy in field evaluation. ful...

2017
Muhammad Ali Dae-Hee Son Sang-Hee Kang

Current transformer (CT) saturation is one of the significant problems for protection engineers. If CT saturation is not tackled properly, it can cause a disastrous effect on the stability of the power system, and may even create a complete blackout. To cope with CT saturation properly, an accurate detection or classification should be preceded. Recently, deep learning (DL) methods have brought...

Journal: :The New England journal of medicine 2013
Ben J Stenson William O Tarnow-Mordi Brian A Darlow John Simes Edmund Juszczak Lisa Askie Malcolm Battin Ursula Bowler Roland Broadbent Pamela Cairns Peter Graham Davis Sanjeev Deshpande Mark Donoghoe Lex Doyle Brian W Fleck Alpana Ghadge Wendy Hague Henry L Halliday Michael Hewson Andrew King Adrienne Kirby Neil Marlow Michael Meyer Colin Morley Karen Simmer Win Tin Stephen P Wardle Peter Brocklehurst

BACKGROUND The clinically appropriate range for oxygen saturation in preterm infants is unknown. Previous studies have shown that infants had reduced rates of retinopathy of prematurity when lower targets of oxygen saturation were used. METHODS In three international randomized, controlled trials, we evaluated the effects of targeting an oxygen saturation of 85 to 89%, as compared with a rang...

Journal: :hepatitis monthly 0
seiyed mohammad ali ghayumi department of internal medicine, shiraz university of medical sciences, shiraz, ir iran abolfazl khalafi-nezhad department of internal medicine, shiraz university of medical sciences, shiraz, ir iran; corresponding author: abolfazl khalafi-nezhad, department of internal medicine, shiraz university of medical sciences, shiraz, ir iran. tel: +98-7116474316, fax: +98-7116474316, e-mail: zahra jowkar department of operative dentistry, school of dentistry, shiraz university of medical sciences, shiraz, ir iran

results roc-derived spo2 threshold of ≤ 94% can predict hypoxemia (pao2 < 60 mmhg) with a sensitivity of 100% and a specificity of 95%. furthermore, there are associations between the roc-derived spo2 threshold of ≤ 97% and detection of hypoxemia (pao2 < 70 mmhg) with a sensitivity of 100% and a specificity of 46%. the accuracy of pulse oximetry was not affected by the severity of liver disease...

Journal: :journal of ultrafine grained and nanostructured materials 2014
mahdi ghazanfari fatemeh johar ahmad yazdani

this paper is a report on the synthesis of the fe3o4@ag core-shell with high saturation magnetization of magnetite nanoparticles as the core, by using polyol route and silver shell by chemical reduction. x-ray diffraction (xrd) and fourier transform infrared spectroscopy analyses confirmed that the particles so produced were monophase. the magnetic properties of the product were investigated by...

2017
Monika Verma Vandana Dixit Kaushik Vinay Pathak

In this paper a novel method for removing haze is given which is based on the Hue Saturation Value color model together with dark channel subtraction. Single image fog/haze removal is a challenging task due to its ill posed nature. As fog/haze increases the brightness of the images captured also increases. In the current wok, a new methodology has been used which involves the subtraction of ext...

2015
Mary Ann Maher

As MOS devices scale to submicron lengths, short-channel effects become more pronounced, and an improved transistor model becomes a necessary tool for the VLSI designer [10]. We present a simple, physically based charge-controlled model. The current in the MOS transistor is described in terms of the mobile charge in the channel, and incorporates the physical processes of drift and diffusion. Th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید