نتایج جستجو برای: signal saturation correction filter

تعداد نتایج: 720932  

2004
Kunpeng Sun Kameshwar Poolla

Robust Linear Filter Design via LMIs and Controller Design with Actuator Saturation via SOS Programming

A. Fallah S. Abbaspour

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

Journal: :iranian journal of radiation research 0
m.n. salihin yusoff school of health science, university science malaysia, kelantan, malaysia a. zakaria school of health science, university science malaysia, kelantan, malaysia

background: butterworth, gaussian, hamming, hanning, and parzen are commonly used spect filters during filtered back-projection (fbp) reconstruction, which greatly affect the quality and size accuracy of image. materials and methods: this study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μci/ml (0.148 mbq/ml) 99mtc conc...

Journal: :Journal of Lightwave Technology 2022

In this paper, to the best of our knowledge, we propose first multi-rate Nyquist-subcarriers modulation (SCM) for C-band 100Gbit/s signal transmission over 50km dispersion-uncompensated link. Chromatic dispersion (CD) introduces severe spectral nulls on optical double-sideband signal, which greatly degrades performance intensity-modulation and direct-detection systems. Based prior knowledge dis...

2017
Austin M. Faught Fang‐Fang Yin Justus Adamson

PURPOSE TrueBeams equipped with the 40 × 30 cm2 Electronic Portal Imaging Devices (EPIDs) are prone to image saturation at the image center when used with flattening filter free (FFF) photon energies. While cine imaging during treatment may not saturate because the beam is attenuated by the patient, the flood field calibration is affected when the standard calibration procedure is followed. Her...

A. Zakaria, M.N. Salihin Yusoff,

Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...

Journal: :Journal of magnetic resonance 2001
R Ouwerkerk P A Bottomley

Signal acquisition in most MRS experiments requires a correction for partial saturation that is commonly based on a single exponential model for T(1) that ignores effects of chemical exchange. We evaluated the errors in (31)P MRS measurements introduced by this approximation in two-, three-, and four-site chemical exchange models under a range of flip-angles and pulse sequence repetition times ...

Journal: :Journal of Lightwave Technology 2022

Kramers-Kronig (KK) receiver shows strong feasibility since the phase can be extracted from detected intensity through Hilbert transform (HT). To reduce complexity and make HT more suitable for practical KK system, approximated as finite impulse response (FIR) filter, i.e., HT-FIR filter. However, Fourier series expansion of filter suffers oscillations around discontinuities further results in ...

2014
Boris S. Karasik Christopher B. McKitterick Daniel E. Prober

In this paper we give a detailed analysis of the expected sensitivity and operating conditions in the power detection mode of a hot-electron bolometer (HEB) made from a few μm of monolayer graphene (MLG) flake which can be embedded into either a planar antenna or waveguide circuit via NbN (or NbTiN) superconducting contacts with critical temperature ~ 14 K. Recent data on the strength of the el...

Journal: :Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular 2009
Denoel Marcelino de Oliveira Andrey Monteiro Francisco José Saraiva Lino Alexandre Siciliano Colafranceschi

Pulmonary artery coarctation often happens in patients with pulmonary atresia. The correction has been usually performed using cardiopulmonary bypass and during the neonatal period, influencing pulmonary artery development and prognosis. Three patients with pulmonary atresia with PDA underwent correction using median sternotomy without cardiopulmonary bypass. The PDA maintained the arterial sat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید