نتایج جستجو برای: transformer oil
تعداد نتایج: 149322 فیلتر نتایج به سال:
Conventional dielectric response measurement techniques, for instance, recovery voltage measurement (RVM), frequency domain spectroscopy (FDS) and polarization–depolarization current (PDC) are effective nondestructive insulation monitoring techniques for oil-impregnated power transformers. Previous studies have focused mainly on some single type of dielectric measurement method. However, the co...
Due to the poor anti-jamming performance, less gas species, low detection accuracy, short life, medium leaking or carbonmonoxide poisoning and other defects that current sensors for gases dissolved in transformer oil have, a SOFC-based multi-component gas sensor has been designed. The physical, chemical and electrochemical mechanisms of gases in the SOFC have been analyzed, and the mathematical...
For examination and diagnostics of the insulation quality of high voltage devices the measurement of partial discharge (PD) is accomplished. The conventional PD measurement according to IEC60270 is in some situations not sensitive enough because of the high interference level in field. The development of an unconventional measuring method using electromagnetic probes is presented. These probes ...
Polychlorinated biphenyl (PCB)-based transformer fluids belong to a class of environmentally persistent mixtures with known toxic effects. Here, we studied the acute effects of Askarel (which contains Aroclor 1260) and two substitute transformer fluids (the silicone oil-based DC561 and the mineral oil-based ENOL C) on rat testicular steroidogenesis. Single intraperitoneal (ip; 10 mg/kg body wei...
Power transformers being the major apparatus in a power system, thus the assessment of transformer operating condition and lifespan have obtained crucial significance in latest years. Dissolved gas analysis (DGA) is a sensitive and reliable technique for the detection of incipient fault condition within oil-immersed transformers, which provides the basis of diagnostic evaluation of equipment he...
Fault diagnosis of power transformers have always drawn the attention among the users, without removing the transformers from the service. Thus it is necessary to detect the incipient fault of a power transformer at an early stage and diagnose properly on optimum way. Dissolved gas analyses (DGA) is widely used to detect incipient faults in oil filled power transformers. Throughout the world, d...
A highly effective adsorbent comprised of the Graphene membrane was created using sonification method in this study. For all we know, resulting employed as an for transformer oil purification first time. The quality treated evaluated through several factors, such acid number TAN(mg KOH/g), color, breakdown voltage, and viscosity. results indicated that exceeded other commercial adsorbents terms...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید