نتایج جستجو برای: water phantom

تعداد نتایج: 566361  

Journal: :Medical physics 2002
Joel Y C Cheung K N Yu C P Yu Robert T K Ho

In calculations for the Leksell Gamma Knife, GammaPlan employs a tissue equivalent material without the presence of a skull bone, while dosimetry work is based on a polystyrene phantom. The compatibility of these dose distributions is uncertain. The Monte Carlo technique was employed to determine the radial dose distributions from a single 14 mm collimator helmet in 160 mm diam phantoms with di...

2017
A. Lagzda R. M. Jones D. Angal-Kalinin J. Jones A. Aitkenhead K. Kirkby R. McKay M. van Herk S. Zeeshan

We investigated the effects of heterogeneous regions on dose deposition of very high-energy electrons (VHEE) using both Geant4 simulations and experiments performed at the CALIFES facility at CERN. Small air and acetal plastic (bone equivalent) cavities were embedded in a water phantom and irradiated with a 197 MeV electron beam. Experimentally determined transverse dose profiles were acquired ...

Journal: :Medical physics 2005
Jean M Moran Donald A Roberts Teamour S Nurushev Larry E Antonuk Youcef El-Mohri Benedick A Fraass

An a-Si Active Matrix Flat Panel Imager (AMFPI) prototype developed in-house has been modified to function as an in-phantom dosimetry system providing high resolution two-dimensional (2-D) data. This Active Matrix Flat Panel Dosimeter (AMFPD) system can be used as a replacement device for standard in-phantom dosimeters, such as scanning ion chambers in water, or film in solid water. The initial...

Journal: :International Journal of Biomedical Imaging 2007
Ji Chen Ernest V. Garcia Russell D. Folks Aharon Peretz James R. Galt

OBJECTIVES SPECT/slow-rotation low-output CT systems can produce streak artifacts in filtered backprojection (FBP) attenuation maps, impacting attenuation correction (AC) in myocardial perfusion imaging. This paper presents an adaptive Bayesian iterative transmission reconstruction (ABITR) algorithm for more accurate AC. METHODS In each iteration, ABITR calculated a three-dimensional prior co...

Journal: :Medical physics 2012
R F Hurley R W Schulte V A Bashkirov A J Wroe A Ghebremedhin H F-W Sadrozinski V Rykalin G Coutrakon P Koss B Patyal

PURPOSE The authors present a calibration method for a prototype proton computed tomography (pCT) scanner. The accuracy of these measurements depends upon careful calibration of the energy detector used to measure the residual energy of the protons that passed through the object. METHODS A prototype pCT scanner with a cesium iodide (CsI(Tl)) crystal calorimeter was calibrated by measuring the...

2008
Vicente Abella Rafael Miró Belén Juste Gumersindo Verdú

The purpose of this work is to obtain the voxelization of a series of tomography slices in order to provide a voxelized human phantom throughout a MatLab algorithm, and the consequent simulation of the irradiation of such phantom with the photon beam generated in a Theratron 780® (MDS Nordion) 60 Co radiotherapy unit, using the Monte Carlo transport code MCNP (Monte Carlo N-Particle), version 5...

A. Rostami, H. Zare, H.R. Sayah Badkhor, K. Anvari, M. Momennezhad, Sh. Naseri,

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

2006
I. Frollo P. Andris V. Juráš Z. Majdišová

Magnetic field distribution measurement and imaging of thin layers using magnetic resonance techniques on biological samples have been performed. The resultant image represents the magnetic susceptibility distribution in the sample. An NMR imaging method susceptible to the homogeneity of magnetic field Gradient Echo was used. Since the investigated physical or biological samples did not generat...

N. Demir, O. Gurler, U. Akar Tarim,

Background: In radiation therapy, water is the phantom material of choice, both for reference and for relative dosimetry measurements. Solid phantoms, however, are more useful for routine measurements because they tend to be more robust and easier to set up than water phantoms. Materials and Methods: FLUKA input data cards have been arranged in sequential order. A simple cylindrical geometry wi...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2009
Tohru Shiga Yuichi Morimoto Naoki Kubo Norio Katoh Chietsugu Katoh Wataru Takeuchi Reiko Usui Kenji Hirata Shinichi Kojima Kikuo Umegaki Hiroki Shirato Nagara Tamaki

UNLABELLED An autoradiography method revealed intratumoral inhomogeneity in various solid tumors. It is becoming increasingly important to estimate intratumoral inhomogeneity. However, with low spatial resolution and high scatter noise, it is difficult to detect intratumoral inhomogeneity in clinical settings. We developed a new PET system with CdTe semiconductor detectors to provide images wit...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید