نتایج جستجو برای: کد mcnp

تعداد نتایج: 7133  

شامرادی‌فر, هادی, شهابی, ایرج, شیرانی, احمد,

In this work, the Isfahan Miniature Neutron Source Reactor (MNSR ) has been simulated using the MCNP code, and reactivity worth of flooding the inner irradiation sites of this reactor in an accident has been calculated. Also, by inserting polyethylene capsules containing water inside the inner irradiation sites, reactivity changes of this reactor in same such accident have been measured, the re...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه اصفهان 1390

بحران انرژی یکی از سه بحران بزرگ سده پیش روی ما است بحران های آب? انرژی و محیط زیست در آینده مشکل آفرینند. به علت رشد بی رویه قیمت سوخت های فسیلی و محدودیت منابع آنها یافتن منایع انرژی جدید ارزان و ایمن و گسترده بسیار مهم و اجتناب ناپذیر است.راکتورهای بستر گلوله ای به عنوان راکتور های نسل چهارم به علت مزایای بسیار ویژه از حیث ایمنی? ‍‍ قیمت تمام شده پایین? بازدهی نسبتا بالا? و رعایت مسایل زیست ...

As the input of MCNP code (Monte Carlo N - Particle code system), a monoenergetic and isotropic point source with the energy rangeg from 0.3 to 10 MeV was placed at the center of a spherical material surrounded by another one. The first shielding material was water and the second one was lead. The total thickness of the shield varied between 2 to 10 mfp. Then, using the output of MCNCP, exposur...

مواد منفجره شامل عناصری از قبیل H، C، N و O با مقدار و نسبت‌های مشخص می‌باشند. عناصر نیتروژن و اکسیژن نسبت به بقیه فراوان‌تر هستند و این مقدار از نیتروژن یک مشخصه عالی برای کشف مواد منفجره می‌باشد. با تعیین میزان نیتروژن انباشته در محیط، می‌توان به احتمال وجود ماده منفجره در آن محیط پی برد. در این مقاله جهت کشف و آشکارسازی مواد منفجره، از تکنیک آنالیز گامای آنی در فعالسازی نوترونی (PGNAA) استفا...

Journal: :Frontiers in Energy Research 2022

Genetic algorithms (GA) are used to optimize the Fast Neutron Source (FNS) core fuel loading maximize a multiobjective function. The FNS has 150 material locations that can be loaded with one of three different materials resulting in over 3E+71 combinations. individual designs evaluated computationally intensive calls MCNP. To speed up optimization, convolutional neural networks (CNN) trained a...

Journal: :Journal of Analytical Atomic Spectrometry 2021

Prompt-gamma activation analysis (PGAA) has been extended and validated to measure large irregularly shaped samples. The detailed sample geometry was implemented in the MCNP-model of setup accurate matrix-effect corrections were obtained.

2007
J. Rataj L. Sklenka

The Paper describes basic information about MCNP calculations and experimental measurements at the VR-1 reactor and their evaluation. The preparation of calculations and verification of the experiments are integral part of the VR-1 reactor operation. The neutronics calculations and analyses are often necessary condition to gain the approval to experiments realization at the reactor VR-1. The pa...

Journal: :Epj Web of Conferences 2023

This document presents the process for a new method developed characterization of delayed gamma-ray radiation fields in pulse reactors like Annular Core Research Reactor (ACRR). The environments used to test this ACRR Central Cavity were various standard irradiation configurations that amounts moderators and shielding. All environment same fission product source energy spectrum. required use si...

Journal: :Journal of Physics: Conference Series 2023

Abstract The Cs 2 LiYCl 6 :Ce crystal (CLYC) is an inorganic scintillator which has been developed for the γ-ray and neutron measurement with high detection efficiency, resolution, no need unfolding technique. To enhance of fast neutron, CLYC 7 Li-enrichment (CLYC7) developed. In this work, response CLYC7 detector to obtained using 137 calibration source calculated Monte Carlo N-Particle transp...

2007
Hashem Miri Hakimabad Hamed Panjeh

Response functions of a 3×3 in. NaI detector, which is mainly used in PGNAA applications, have been calculated by using MCNP-4C code. Calculated results are compared with measured data by using standard γ-ray sources to check their accuracy. γ-rays from radioisotope sources were used in the range from 0.081 to 4.438 MeV for this determination. Through the precise modeling of the detector struct...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید