نتایج جستجو برای: 3d gel dosimetry

تعداد نتایج: 299187  

Mohsen layegh Navid nateghi

Introduction: Today different uses of multileaf collimators(MLC) in different techniques of radiotherapy are common. Due to the use of this facility it is possible to have maximum radiation dose to target volumes and minimum radiation dose to critical tissues surronding treatment volumes. But there are numerouse Linear accelerators in IRAN without MLC. Because of high price of...

Journal: :The British journal of radiology 2000
M McJury M Oldham V P Cosgrove P S Murphy S Doran M O Leach S Webb

New, complex radiotherapy delivery techniques require dosimeters that are able to measure complex three-dimensional dose distributions accurately and with good spatial resolution. Polymer gel is an emerging new dosimeter being applied to these challenges. The aim of this review is to present a practical overview of polymer gel dosimetry, including gel manufacture, imaging, calibration and appli...

2018
Wen-zhao Sun Dan-dan Zhang Ying-lin Peng li Chen De-hua Kang Bin Wang Xiao-wu Deng

BACKGROUND Conventional phantom-based planar dosimetry (2D-PBD) quality assurance (QA) using gamma pass rate (GP (%)) is inadequate to reflect clinically relevant dose error in intensity-modulated radiation therapy (IMRT), owing to a lack of information regarding patient anatomy and volumetric dose distribution. This study aimed to evaluate the dose distribution accuracy of IMRT delivery for na...

2004
Madoka BABA Aki ISHII Yukihisa SUZUKI Soichi WATANABE Masao TAKI

High-molecular gel containing capsulate thermo-chromic liquid crystal is made to visualize three-dimensional distribution of electromagnetic power absorption. A preliminary experiment is performed at frequency of 1.5GHz. As a result of the experiment, the three-dimensional distribution of electromagnetic power absorption is clearly visualized. The result shows that the gel can be used as a phan...

2009
Jouni Uusi-Simola

Boron neutron capture therapy (BNCT) is a form of chemically targeted radiotherapy that utilises the high neutron capture cross-section of boron-10 isotope to achieve a preferential dose increase in the tumour. The BNCT dosimetry poses a special challenge as the radiation dose absorbed by the irradiated tissues consists of several dose components with different relative biological effectiveness...

2013
Bo Liu Justus Adamson Anna Rodrigues W Ansbacher I M Gagne

Purpose: To develop and validate a pre-treatment EPI dosimetry method on Varian TrueBeam linacs using continuous imaging, with reconstruction in a 3D cylindrical phantom geometry. Methods: Delivery of VMAT plans with continuous imaging is currently possible only in Research Mode on TrueBeam linacs, with images acquired in a proprietary format. An earlier technique was adapted to take advantage ...

Ahad Zainali, Leila Mahani

Introduction: Inclusion of inhomogeneities such as air-filled cavities in the head and neck treatment fields may result in potential dosimetric disagreement which was caused by electronic disequilibrium. Most of treatments planning systems (TPS) are not able to predict dose distribution of inhomogeneous regions accurately. EBT2 films are used frequently in radiotherapy quality ass...

Ghorban Safaeian, Mina Nouri, Mohammad Hosein Bahreyni Toossi Mohammad Taghi Bahreyni Toossi Shahram Bayani

Introduction: The objective of this work is to study the ability of MRI normoxic polymer gel dosimetry system to be used to verify the calculated dose distribution, in a simple geometry, in clinical radiotherapy. Materials and Methods:  Initially, 2 liters of the normoxic MAGAT polymer gel was prepared and then poured into two cylindrical Perspex phantom (simu...

Journal: :Applied sciences 2021

Much of the complex medical physics work requires radiation dose delivery, which dosimeters to accurately measure three-dimensional distribution with good spatial resolution. MAGIC-f polymer gel is one emerging new widely used in research. The purpose this study was present an overview dosimetry, using gel, including its composition, manufacture, imaging, calibration, and application In review,...

Journal: :Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention 2007
Ameet K. Jain Anton Deguet Iulian Iordachita Gouthami Chintalapani J. Blevins Y. Le E. Armour Everette Clif Burdette Danny Y. Song Gabor Fichtinger

Intra-operative guidance in Transrectal Ultrasound (TRUS) guided prostate brachytherapy requires localization of inserted radioactive seeds relative to the prostate. Seeds were reconstructed using a typical C-arm, and exported to a commercial brachytherapy system for dosimetry analysis. Technical obstacles for 3D reconstruction on a non-isocentric C-arm included pose-dependent C-arm calibration...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید