نتایج جستجو برای: aseptic loosening

تعداد نتایج: 8237  

2015
Farhan Syed Edward Jenner Mohammad Faisal

Metal allergy is an unusual complication of joint replacement that may cause aseptic loosening and necessitate joint revision surgery. We present the case of nickel allergy causing aseptic loosening following patellofemoral joint replacement (PFJR) in a 54-year-old male. Joint revision surgery to a nickel-free total knee replacement was performed with good results. Our literature review shows t...

Journal: :The Journal of bone and joint surgery. British volume 1991
P Roberts D Chan R J Grimer R S Sneath J T Scales

Over a 16-year period, 135 custom-made distal femoral prostheses, based on a fully constrained Stanmore-type knee replacement, were used in the treatment of primary malignant or aggressive benign tumours. Survivorship analysis showed a cumulative success rate of 72% at five years and 64% at seven years. Intact prostheses in 91% of the surviving patients gave good or excellent functional results...

Journal: :Journal of shoulder and elbow surgery 2010
Gordon I Groh

BACKGROUND Aseptic loosening of glenoid components is a common problem associated with total shoulder arthroplasty and one cause for failure. A new cementless fluted glenoid component was developed and has shown excellent bony ingrowth in a canine model. HYPOTHESIS Clinical utilization of this cementless fluted pegged glenoid component in total shoulder arthroplasty would lower rates of radio...

2016
Ludger Gerdesmeyer Munjed Al Muderis Hans Gollwitzer Norbert Harrasser Martin Stukenberg Maria-Angela Clifford Andreas Toepfer

BACKGROUND Cementless fixation of total hip arthroplasties (THAs) is often favored in young, high-demanding patients due to the conservation of valuable bone-stock and easier revision if loosening has occurred. Long-term outcome data of the spongy metal structured implant used in the present study in patients younger than 65 years are still lacking. METHODS We conducted a retrospective chart ...

Journal: :Journal of orthopaedic surgery 2012
David J Cossetto Anil Goudar

PURPOSE To report the mid-term outcome of a modular, cementless, proximally hydroxyapatitecoated, anatomic femoral stem in total hip arthroplasty (THA). METHODS 160 consecutive patients aged 42 to 92 (mean, 70) years underwent 185 cementless THAs for primary osteoarthritis or femoral neck fractures. All procedures were performed by a single surgeon using the same modular, cementless, proximal...

Journal: :BMC Musculoskeletal Disorders 2004
Alexander O El-Warrak Marvin Olmstead Rebecca Schneider Lorenz Meinel Regula Bettschart-Wolfisberger Margarete K Akens Joerg Auer Brigitte von Rechenberg

BACKGROUND Aseptic loosening of hip prosthesis as it occurs in clinical cases in human patients was attributed to wear particles of the implants, the response of the tissue dominated by macrophages and the production of inflammatory mediators and matrix degrading enzymes; however, the cascade of events initiating the process and their interaction regarding the time course is still open and disc...

Journal: :The Journal of bone and joint surgery. British volume 2010
K Mannan M A R Freeman G Scott

The outcome at ten years of 100 Freeman hip stems (Finsbury Orthopaedics, Leatherhead, United Kingdom) retaining the neck with a proximal hydroxyapatite coating in a series of 52 men (six bilateral) and 40 women (two bilateral), has been described previously. None required revision for aseptic loosening. We have extended the follow-up to 20 years with a minimum of 17 years. The mean age of the ...

Journal: :Annals of the rheumatic diseases 1997
A Sabokbar Y Fujikawa S Neale D W Murray N A Athanasou

OBJECTIVE In aseptic loosening, a heavy macrophage response to biomaterial wear particles is commonly found in arthroplasty tissues. The aim of this study was to discover if these cells contribute to the bone resorption of aseptic loosening by differentiating into osteoclasts. METHODS Macrophages were isolated from the pseudocapsule and pseudomembrane of loose cemented and uncemented hip arth...

Journal: :Journal of the Medical Association of Thailand = Chotmaihet thangphaet 2012
Rapeepat Narkbunnam Keerati Chareancholvanich

BACKGROUND The number of primary total knee replacement procedures has rapidly increased worldwide because of the high success rates. The incidence of failure of total knee replacements has concurrently increased. Determining the causes of failure is very important for devising treatment and plan for future prevention strategies. MATERIAL AND METHOD A retrospective study was done with patient...

2017
Jie J. Yao Eric A. Lewallen William H. Trousdale Wei Xu Roman Thaler Christopher G. Salib Nicolas Reina Matthew P. Abdel David G. Lewallen Andre J. van Wijnen

We evaluated recently published articles relevant to the biological effects of titanium dioxide (TiO2) particles on local endogenous cells required for normal bone homeostasis, repair, and implant osseointegration. Structural characteristics, size, stability, and agglomeration of TiO2 particles alter the viability and behavior of multiple bone-related cell types. Resulting shifts in bone homeos...