نتایج جستجو برای: curved root canals

تعداد نتایج: 161034  

Journal: :International endodontic journal 2003
O A Peters C I Peters K Schönenberger F Barbakow

AIM To investigate physical parameters for ProTaper nickel-titanium (NiTi) rotary instruments whilst preparing curved canals in maxillary molars in vitro. METHODOLOGY A novel torque-testing platform was used to prepare root canals in 15 extracted human maxillary molars with ProTaper rotary instruments. Peak torque and force was registered along with numbers of rotations required to shape the ...

Journal: :Brazilian oral research 2015
Guven Kayaoglu Ilkay Peker Mustafa Gumusok Cigdem Sarikir Aylin Kayadugun Ozlem Ucok

The aims of this study were to evaluate the number of roots/root canals in the mandibular anterior teeth of a Turkish population, to assess the relationship between gender or age and the frequency of two canals in a single root, and to determine the symmetry in root/root canal numbers between contralateral sides among patients. Cone-beam computed tomography images (n = 1128; 6253 teeth) taken a...

Journal: :International endodontic journal 2000
S A Thompson

The nickel-titanium alloy Nitinol has been used in the manufacture of endodontic instruments in recent years. Nitinol alloys have greater strength and a lower modulus of elasticity compared with stainless steel alloys. The super-elastic behaviour of Nitinol wires means that on unloading they return to their original shape following deformation. These properties are of interest in endodontology ...

Journal: :Iranian endodontic journal 2016
Marcelo Santos Coelho Carlos Eduardo Fontana Augusto Shoji Kato Alexandre Sigrist de Martin Carlos Eduardo da Silveira Bueno

INTRODUCTION The aim of this in vitro study was to evaluate the effects of establishing glide path on the centering ability and preparation time of two single-file reciprocating systems in mesial root canals of mandibular molars. METHODS AND MATERIALS Sixty extracted mandibular molars with curvatures of 25-39 degrees and separate foramina for the mesiobuccal and mesiolingual canals, were divi...

Journal: :Acta stomatologica Croatica 1983
J Sutalo

The purpose of the investigation was to establish the exact number of root canals in the maxillary first permanent molar, their direction, type and relation, based upon a large number of random samples. Randomly chosen 443 maxillary first permanent molars (221 left and 222 right) were investigated with the aim to get more knowledge into the morpho­ logy of the endodontic space. One canal in the...

Journal: :International endodontic journal 2009
M Rahimi P Parashos

AIM To report on a conservative approach for removal of a fractured file in the severely curved apical portion of the distobuccal canal of a mandibular molar. SUMMARY With the assistance of stainless steel hand files and a chloroform-dipped gutta-percha cone, a fractured rotary NiTi instrument was successfully removed. The use of this technique may assist in removal of loose instrument fragme...

Journal: :Medicina oral, patologia oral y cirugia bucal 2007
Mercedes Pérez Heredia Javier Clavero González Carmen María Ferrer Luque María Paloma González Rodríguez

AIM To compare the apical sealing in mesio-buccal canals of extracted molars obturated with low-temperature thermoplasticized gutta-percha or cold lateral condensation techniques using a .06 or a .02 mm/mm tapered gutta-percha master cone. The secondary aim was to evaluate the depth of spreader penetration in root canals using a .06 or a .02 mm/mm tapered gutta-percha master cone. METHODOLOGY...

Journal: :Middle black sea journal of health science 2022

Objective: The aims of the study are to investigate effect surface treatment process on prolonging life rotary instruments against cyclic fatigue and coating corrosion resistance Ni-Ti files.Methods: This was carried out in two stages. In first one, a total 120 (25/.04 taper) from 3 brands (HeroShaper, RaCe, TF) were selected. Sixty them anodized then all tested simulated root canals with diffe...

Journal: :Journal of Khyber College of Dentistry 2021

Objective:
 To assess the life of two different rotary nickel-titanium (NiTi) instruments in curved canals with complete protocol, by using 360°rotation motion and reciprocating motion.
 Materials Methods:
 About one hundred seventy extracted maxillary mandibular molars were taken from which root selected randomly divided 2 groups, for analyzing number uses files. One prepared Hy...

Journal: :Journal of endodontics 2003
Jeff R Ward Peter Parashos Harold H Messer

The removal of fractured rotary nickel-titanium instruments from small, curved root canals is one of the most complex operative procedures in endodontics. There have been many different devices and techniques developed to remove fractured instruments, but none are consistently successful and all show a high incidence of canal damage such as perforation. A technique using a staging platform and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید