نتایج جستجو برای: depression defibrillators

تعداد نتایج: 143198  

Journal: :Journal of the American College of Cardiology 2018

Journal: :Journal of the American College of Cardiology 2008

Journal: :Journal of the American College of Cardiology 2006

Journal: :Herzschrittmachertherapie + Elektrophysiologie 2016

Journal: :iranian journal of public health 0
leila dana-alamdari dept. of nutrition, tabriz university of medical sciences, tabriz, iran. sorayya kheirouri dept. of nutrition, tabriz university of medical sciences, tabriz, iran. seyed gholamreza noorazar research center of psychiatry and behavioral sciences, tabriz university of medical sciences, tabriz, iran.

we investigated the association between serum 25(oh) d levels and depressive symptoms in patients with major depressive disorder (mdd).eighty-five adults, 44 drug free patients with mdd and 41 apparently healthy controls, participated in the study. the hamilton depression rating scale was used to assess severity of major depression. mental health of the controls was assessed according to dsm-iv...

Journal: :Circulation 1978
R A DeSilva B Lown

Recommendations have been made recently that the energy output of present-day defibrillators be increased above the 400 wsec limit. These recommendations are based largely on experimental studies in animals. We report a case of a man weighing 190.1 kg (418.2 lb), successfully resuscitated with a single 400 wsec shock after a prolonged episode of ventricular fibrillation. The observation in this...

Journal: :Current Controlled Trials in Cardiovascular Medicine 2001
Bruce L Wilkoff

All of the prospective multicenter trials that support the use of implantable defibrillators have used single chamber pacemakers/implantable cardiovertor defibrillators (ICDs). Despite the significantly increased cost of dual chamber pacemaker/ICD devices and the lack of outcome data, these devices accounted for approximately two-thirds of the ICDs implanted in the United States during the 12 m...

Journal: :Circulation 1979
J A Gascho R S Crampton M L Cherwek J N Sipes F P Hunter W M O'Brien

Conventional defibrillators which stored no more than 400 J and used damped sine wave pulses defibrillated 240 of 253 (95%) episodes of ventricular fibrillation (VF) in 94 prospectively assessed resuscitations in 88 adults. Shocks of 80--240 J (under 3 J/kg) delivered to the chest wall defibrillated more often than higher energy levels. Defibrillation rate did not correlate with weight. Defibri...

نمودار تعداد نتایج جستجو در هر سال