نتایج جستجو برای: diode dosimetry

تعداد نتایج: 28903  

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2011
Michael G Stabin Robert M Sharkey Jeffry A Siegel

There is a long history of absorbed dose calculations being performed to evaluate the risks involved in the application of radiopharmaceuticals to medical studies. In the 1940s, Marinelli, Quimby, and Hine (1–3) published a set of articles that presented a summary and approach to radionuclide dosimetry. In 1956 Loevinger et al. (4) summarized the field at that point, and then in 1968 the newly ...

اربابی, عظیم, بلوری, بهرام, ندایی, حسن, قهرمان اصل, روح اله,

  Background & Aim: Nowadays, radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Polymer gel dosimeters consist of an aqueous mixture of monomers and a gelling agent, which after irradiation, 3D dose distribution is acquired by using imaging techniques. The aim of this study is to evaluate the application and capability of normoxic polym...

Journal: :Radiation protection dosimetry 2011
E A Ainsbury E Bakhanova J F Barquinero M Brai V Chumak V Correcher F Darroudi P Fattibene G Gruel I Guclu S Horn A Jaworska U Kulka C Lindholm D Lloyd A Longo M Marrale O Monteiro Gil U Oestreicher J Pajic B Rakic H Romm F Trompier I Veronese P Voisin A Vral C A Whitehouse A Wieser C Woda A Wojcik K Rothkamm

The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and em...

Journal: :Annali dell'Istituto superiore di sanita 2009
François Trompier Celine Bassinet Albrecht Wieser Cinzia De Angelis Daniela Viscomi Paola Fattibene

Dosimetry based on the detection by electron paramagnetic resonance (EPR) spectroscopy of ionizing radiation-induced radicals is an established method for the retrospective dosimetry of past exposures and the dosimetry of potentially exposed persons in radiological emergencies. The dose is estimated by measuring the physical damage induced in materials contained in objects placed on or next to ...

2014
Yves De Deene Andrew Jirasek

Three-dimensional (3D) gel dosimetry has a unique role to play in safeguarding conformal radiotherapy treatments as the technique can cover the full treatment chain and provides the radiation oncologist with the integrated dose distribution in 3D. It can also be applied to benchmark new treatment strategies such as image guided and tracking radiotherapy techniques. A major obstacle that has hin...

2014
L J Schreiner

Since the introduction of volumetric chemical dosimetry with Fricke gel dosimeters in the 1980s, three-dimensional (3D) dosimetry has been a promising technique for the clinic, since it provides a unique methodology for 3D dose measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. In the last decad...

2014
Carlos Eduardo deAlmeida Ricardo Ochoa Marilene Coelho de Lima Mariano Gazineu David Evandro Jesus Pires José Guilherme Peixoto Camila Salata Mario Antônio Bernal

High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brac...

2010
Gareth Roberts

Routine internal dose exposures are typically (in the UK nuclear industry) less than external dose exposures: however, the costs of internal dosimetry monitoring programmes can be significantly greater than those for external dosimetry. For this reason decisions on when to apply routine monitoring programmes, and the nature of these programmes, can be more critical than for external dosimetry p...

2015
Ganesh Narayanasamy Travis Zalman Chul S. Ha Niko Papanikolaou Sotirios Stathakis

The purpose of this study is to evaluate the use of the Dosimetry Check system for patient-specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the patient's CT scans. Instead of making dose co...

Journal: :iranian journal of medical physics 0
m. taghizadeh dabbagh m.sc. in medical physics, medical imaging center, imam hosein hospital, shahrood college of medical sciences, shahrood, iran. m. allahverdi assistant professor, medical physics dept., cancer institute, imam khomeini hospital, tehran university of medical sciences, tehran, iran. m. esfahani m.sc. in medical physics, cancer institute, imam khomeini hospital, tehran university of medical sciences, tehran, iran. p. haddad associate professor, radiation therapy dept., cancer institute, imam khomeini hospital, tehran university of medical sciences, tehran, iran.

introduction: during radiotherapy, high accuracy in the dose delivery is required because there is a strong  relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. in  many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. in general,  the uncertainty in the dose delivered should fall within  ± 5% of the...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید