نتایج جستجو برای: dose distribution verification

تعداد نتایج: 975918  

2006
Lu Wang Jinsheng Li Kamen Paskalev Peter Hoban Wei Luo Lili Chen Shawn McNeeley Robert Price Charlie Ma

A 3D treatment-planning system (TPS) for stereotactic intensity-modulated radiotherapy (IMRT) using a micro-multileaf collimator has been made available by Radionics. In this work, we report our comprehensive quality assurance (QA) procedure for commissioning this TPS. First, the accuracy of stereotaxy established with a body frame was checked to ensure accurate determination of a target positi...

2015
Young K Lee Anthony T Kim Peiying Zhao Aliaksandr Karotki

Craniospinal irradiation (CSI) using IMRT allows dose sparing to organs-at-risk (OAR) whilst conforming the dose to the target volume. Due to the complexity of treatment involving several isocenters, the dose distribution created by the inverse-planned segmented fields must be verified prior to treatment. We propose and test methods to verify dose delivery using commonly available dosimetry equ...

F Seif, M Kargaran M R Bayatiani, S Hamidi

Background: Considering that some vital organs exist in the head and neck region, the treatment of tumors in this area is a crucial task. The existence of air cavities, namely sinuses, disrupt the radiotherapy dose distribution. The study aims to analyze the effect of maxillary, frontal, ethmoid and sphenoid sinuses on radiotherapy dose distribution by Monte Carlo method.Materials and Methods: ...

2013
Yun Liang Gwe‐Ya Kim Todd Pawlicki Arno J. Mundt Loren K. Mell

The purpose of this study was to develop dosimetry verification procedures for volumetric-modulated arc therapy (VMAT)-based total marrow irradiation (TMI). The VMAT based TMI plans were generated for three patients: one child and two adults. The planning target volume (PTV) was defined as bony skeleton, from head to mid-femur, with a 3 mm margin. The plan strategy similar to published studies ...

Journal: :Japanese Journal of Radiological Technology 2021

Purpose The purpose was to study comparative evaluation of calculated dose distribution by X-ray Voxel Monte Carlo (XVMC) for calculation in Acuros XB (AXB). commissioning and head neck volumetric modulated arc therapy (VMAT) clinical cases were compared AXB Eclipse XVMC Monaco. Methods For TrueBeam at 6 MV, we the simple rectangle, heterogeneity correction, multileaf collimator (MLC) character...

Journal: :iranian journal of radiation research 0
k. adinehvand borujerd islamic azad university, borujerd, iran m.h. zahmatkesh novin radiation medicine institute, tehran, iran m.r aghamiri division of radiation medicine, shahid beheshti university, tehran, iran sh. akhlaghpour department of radiology, tehran university of medical sciences, tehran, iran s. bagheri novin radiation medicine institute, tehran, iran

background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...

Journal: :Zeitschrift fur medizinische Physik 2011
Thomas Goetzfried Mark Rickhey Marius Treutwein Oliver Koelbl Ludwig Bogner

Patient-specific verification of intensity-modulated radiation therapy (IMRT) plans can be done by dosimetric measurements or by independent dose or monitor unit calculations. The aim of this study was the clinical evaluation of IMRT verification based on a fast Monte Carlo (MC) program with regard to possible benefits compared to commonly used film dosimetry. 25 head-and-neck IMRT plans were r...

نمودار تعداد نتایج جستجو در هر سال