Experiments were performed in a cylindrical 0.14 m diameter bubble column with a metal perforated plate. Air and aqueous solutions of glycerol with viscosity 1–22 mPa s were the phases. Gas holdup was measured and plotted against the gas flow rate. The critical point where the homogeneous–heterogeneous regime transition begins was determined by the drift-flux plot of the primary data. The homog...