نتایج جستجو برای: glucose sensor

تعداد نتایج: 370589  

Journal: :Biomed. Signal Proc. and Control 2016
Alexandros C. Charalampidis Konstantinos Pontikis Georgios D. Mitsis George Dimitriadis Vaia Lampadiari Vasilis Z. Marmarelis Apostolos Armaganidis George P. Papavassilopoulos

This paper deals with the estimation of glucose levels in ICU patients by the application of statistical filter theory to the data provided by a commercial continuous glucose monitoring system using a microdialysis sensor. Kalman and particle filtering are applied to simple models of the glucose dynamics. The particle filter enables the joint filtering and calibration of the sensor. The results...

2002
Jianzhong Zhu Ziqiang Zhu Zongsheng Lai Rong Wang Xiaoming Guo Xiaqin Wu Guoxiong Zhang Zongrang Zhang Yiting Wang Zongyou Chen

A planar amperometric glucose microsensor based on glucose oxidase immobilized by chitosan film on Prussian Blue layer has been developed. The experimental results show that the optimum detection potential is 50 mV (versus Ag/AgCl) and the optimum pH is 6.5. Under the selective conditions the sensor exhibits excellent sensitivity of 98 nA/M and a linear range of 0.1-6.0 mM. The apparent Michane...

2016
Dongmin Seo Sung-Ho Paek Sangwoo Oh Sungkyu Seo Se-Hwan Paek

The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Usin...

Journal: :Clinical chemistry 2007
Graham J Worsley Guilhem A Tourniaire Kathryn E S Medlock Felicity K Sartain Hazel E Harmer Michael Thatcher Adrian M Horgan John Pritchard

BACKGROUND We recently described a holographic optical sensor with improved selectivity for glucose over fructose that was based on a thin-film polymer hydrogel containing phenylboronic acid receptors. The aim of the present work was to measure glucose in human blood plasma as opposed to simple buffers and track changes in concentration at a rate mimicking glucose changes in vivo. METHODS We ...

2013
Xiao-Yan Yue Yi Zheng Ye-Hua Cai Ning-Ning Yin Jian-Xin Zhou

Accurate and timely glucose monitoring is essential in intensive care units. Real-time continuous glucose monitoring system (CGMS) has been advocated for many years to improve glycemic management in critically ill patients. In order to determine the effect of calibration time on the accuracy of CGMS, real-time subcutaneous CGMS was used in 18 critically ill patients. CGMS sensor was calibrated ...

2014
Ala'aldeen Al-Halhouli Stefanie Demming Laila Alahmad Andreu Llobera Stephanus Büttgenbach

This paper presents two PDMS photonic biosensor designs that can be used for continuous monitoring of glucose concentrations. The first design, the internally immobilized sensor, consists of a reactor chamber, micro-lenses and self-alignment structures for fiber optics positioning. This sensor design allows optical detection of glucose concentrations under continuous glucose flow conditions of ...

Journal: :Diabetes technology & therapeutics 2012
Thomas Zueger Peter Diem Stavroula Mougiakakou Christoph Stettler

BACKGROUND AND AIMS Data on the influence of calibration on accuracy of continuous glucose monitoring (CGM) are scarce. The aim of the present study was to investigate whether the time point of calibration has an influence on sensor accuracy and whether this effect differs according to glycemic level. SUBJECTS AND METHODS Two CGM sensors were inserted simultaneously in the abdomen on either s...

Journal: :Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia 2007
Tereza Jadviscokova Zuzana Fajkusova Maria Pallayova Jiri Luza Galina Kuzmina

AIMS Continuous glucose monitoring (CGM) using transcutaneous sensors is becoming a sophisticated method to control and regulate glucose metabolism. The transcutaneous sensor of the CGM system (CGMS Medtronic Minimed, Northridge, CA, USA) is chosen to measure glucose concentration in interstitial fluid up to three days after insertion even though its function remains stable for a longer period....

Journal: :Diabetes care 2008
Jeroen Hermanides Iris M Wentholt Augustinus A Hart Joost B Hoekstra J Hans DeVries

OBJECTIVE Data investigating the possible disturbing influence of insulin in the vicinity of continuous glucose monitoring (CGM) is lacking. We investigated the hypothesis that high local insulin concentrations would interfere with sensor readings. RESEARCH DESIGN AND METHODS Two microdialysis sensors were inserted in the periumbilical region of 10 continuous subcutaneous insulin infusion (CS...

Journal: :The Journal of clinical investigation 2004
Laurie Goodman

High-tech coal mine canary One of coal mining's earliest systems for warning of the presence of methane gas, the canary in the coal mine, though low-tech, was extremely effective and rather easy to read: if the bird died, miners had to get out of the shaft. Today, the search for means to monitor for signs of danger continues. At an annual checkup, one could be given a whole battery of tests, ea...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید