Introduction: In diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. Monte Carlo methods are used due to the high complexity and cost of patient-specific phantom construction. The high complexity of the digitized phantoms greatly increases the time and computational task of the Monte Carlo calculati...

Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...

Journal: :iranian journal of medical physics 0
asghar mesbahi department ofmedical physics, medical school, tabriz university of medical sciences,,tabriz, iran. 2- department ofradiation oncology, imam hospital, tabriz, iran. ismail zergoug 3-department of radiotherapy, emir abdelkaderanti-cancer center, oran, algeria

introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linea...

2008
Danyelle M. Townsend Yefim Manevich Lin He Steven Hutchens Christopher J. Pazoles Kenneth D. Tew

Danyelle M. Townsend, Yefim Manevich, Lin He, Steven Hutchens, Christopher J. Pazoles, Kenneth D. Tew Departments of Pharmaceutical and Biomedical Sciences, Cell and Molecular Pharmacology and Experimental Therapeutics, Medical University of South Carolina, 96 Johnathan Lucas St. P.O., Charleston, SC 29425 4 Novelos Inc., One Gateway Ctr, Newton, MA 02458. Running head: GSTπ catalyzes S-glutath...

Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...

2014
Jeungchan Lee Vitaly Napadow Jieun Kim Seunggi Lee Woojin Choi Ted J. Kaptchuk Kyungmo Park

In a clinical setting, acupuncture treatment consists of multiple components including somatosensory stimulation, treatment context, and attention to needle-based procedures. In order to dissociate somatosensory versus contextual and attentional aspects of acupuncture, we devised a novel form of placebo acupuncture, a visual manipulation dubbed phantom acupuncture, which reproduces the acupunct...

2001
Habib Zaidi

Received 12/27/2000; revised 2/26/2001; accepted 3/14/2001. For correspondence or reprints contact: Habib Zaidi, Ph.D., Division of Nuclear Medicine, Geneva University Hospital, CH-1211 Geneva, Switzerland. Tel: 41 22 372 72 58, Fax: 41 22 372 71 69, E-mail: [email protected] A new method to assess the scatter component in positron emission tomography (PET) based on estimating the low-freque...

1999
S. M. HANNA

Most radiation therapy machines are based on microwave linear accelerators. The majority of medical accelerators use frequencies in the S-band range. Having a compact accelerator allows for a wide range of treatments. The size and weight of the accelerator is substantially reduced if a higher frequency is used. X-band frequencies are suitable for such applications. The X-band accelerator techno...

Journal: :Physics in medicine and biology 2005
Jay Wu Keh-Shih Chuang Ching-Han Hsu Meei-Ling Jan Ing-Ming Hwang Tzong-Jer Chen

Fully three-dimensional (3D) positron emission tomography (PET) can achieve high sensitivity of coincidence events, but the absence of inter-slice septa inevitably leads to increased scattered events. The scattered events can represent as much as 50% of the total detected events. In this research, we proposed a scatter correction method for 3D PET based on beam stoppers and dual-energy window a...

2014
Timothy D. Solberg Paul M. Medin Ezequiel Ramirez Chuxiong Ding Ryan D. Foster John Yordy

The purpose of this study is to describe the comprehensive commissioning process and initial clinical performance of the Vero linear accelerator, a new radiotherapy device recently installed at UT Southwestern Medical Center specifically developed for delivery of image-guided stereotactic ablative radiotherapy (SABR). The Vero system utilizes a ring gantry to integrate a beam delivery platform ...