نتایج جستجو برای: hip resurfacing function

تعداد نتایج: 1272080  

Journal: :The Journal of bone and joint surgery. British volume 2005
R Itayem A Arndt L Nistor D McMinn A Lundberg

The Birmingham hip resurfacing metal-on-metal arthroplasty was introduced in 1997 and has shown promising short- to mid-term results. We used radiostereophotogrammetric analysis (RSA) to study the stability of 20 resurfacing arthroplasties over a follow-up period of 24 months. Radiological examinations for RSA were performed immediately after surgery and at two, six, 12 and 24 months after oper...

Journal: :The Journal of bone and joint surgery. British volume 2006
P E Beaulé P A Campbell R Hoke F Dorey

During hip resurfacing arthroplasty, excessive valgus positioning or surgical technique can result in notching of the femoral neck. Although mechanical weakening and subsequent fracture of the femoral neck are well described, the potential damage to the retinacular vessels leading to an ischaemic event is relatively unknown. Using laser Doppler flowmetry, we measured the blood flow in 14 osteoa...

Journal: :The Journal of bone and joint surgery. British volume 2011
W van der Weegen H J Hoekstra T Sijbesma E Bos E H Schemitsch R W Poolman

We systematically reviewed the peer-reviewed literature to relate the survival of hybrid metal-on-metal hip resurfacing arthroplasty devices to a National Institute of Clinical Excellence (NICE) benchmark for choosing a primary total hip replacement, which is a survival rate of 90% at a follow-up of ten years. A total of 29 articles (10 621 resurfaced hips) met the inclusion criteria. The mean ...

Journal: :International Orthopaedics 2010

Journal: :The Journal of bone and joint surgery. British volume 2010
R Cordingley L Kohan B Ben-Nissan

The major advantage of hip resurfacing is the decreased amount of bone resection compared with a standard total hip replacement. Fracture of the femoral neck is the most common early complication and poor bone quality is a major risk factor. We undertook a prospective consecutive case control study examining the effect of bone mineral density changes in patients undergoing hip resurfacing surge...

Journal: :The Journal of bone and joint surgery. British volume 2006
D R Boardman F R Middleton T G Kavanagh

As metal-on-metal arthroplasty becomes more widespread, concerns are being raised about the potential dangers of metal particulate debris. We present the case of a benign psoas mass secondary to the presence of such particles. The mass was excised and the hip resurfacing subsequently revised to a total hip replacement.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید