نتایج جستجو برای: liquid membrane electrode

تعداد نتایج: 654404  

E. Baghdar M. Aghaie M. Giahi M. H. Fekri S. Farhadi

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...

ژورنال: سلامت و محیط زیست 2020

Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determin...

Journal: :Clinica chimica acta; international journal of clinical chemistry 1970
L A Pioda W Simon H R Bosshard C H Curtius

The potassium-selective glass membranes like KAS,,_, and NAS,,_, are approx. IO times more sensitive to K+ than to Na +lp3. Since the concentration ratio of Na+/K+ in blood serum is around 35-40 and since there is at best a K+ over Naf selectivity in glass electrodes of IO, a separate measurement of the Na+ concentration is needed to correct the reading of the K+ sensor 4. Because of the depend...

2014
M. N. Anas M. N. Ahmad

This paper deals with the development of a liquid measuring instrumentation using the popular tetrapolar electrode configuration. The system consists of four-electrode ring shape using Cromium metal plate and a small measurement. The developed instrument is calibrated with the help of prepared saline solution prepared in lab. A liquid of known parameter is placed inside the measurement cell and...

2001
Changzhi Zhao Songyun Xu Zhaohong Ding Guoliang Zhao Naoyoshi Egashira

A novel fiber-optic electrochemiluninescence sensor has been developed. It can be conveniently applied by placing into the sample solution in a manner similar to a conventional ion selective electrode, without requiring liquid luminous reagent and a flowing system. The sensor is consisted of an independent probe and a case for exclusion the ambient light, allowing the sample solution to pass th...

Journal: :Journal of The Electrochemical Society 2021

Aqueous electrolytes are very effective for supercapacitor applications but their narrow electrochemical potential window (∼1 V) and associated limited energy currently limits use. Here, we demonstrate a new strategy to enlarge the by designing an artificial interface ( ai ). An was achieved via mixture of siloxanes doped with ionic liquid, 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfony...

Journal: :Journal of physics 2022

Abstract Water management is a critical challenge in low temperature (LT) Proton Exchange Membrane Fuel Cells (PEM FC); condensed liquid appears mainly at the cathode side, where water from reduction reaction generated. Differences concentration may result transfer of to anode side across membrane electrode assembly (MEA). Excessive can negatively affect fuel cell performance, causing efficienc...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2010
Yumi Yoshida Satoshi Yamaguchi Kohji Maeda

An indium tin oxide glass electrode coated with poly(3,4-ethylenedioxythiophene), PEDOT, PEDOT-ITOE, was proposed as an electrode workable as both a reference electrode and a counter one, a reference/counter electrode, in an organic phase and applied to a thin-layer cell of a two-electrode system for voltammetry at the liquid | liquid interface. By oxidizing the PEDOT film by 50% and doping a s...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2001
M Shamsipur M R Ganjali A Rouhollahi

A PVC-based membrane electrode for lead ions based on hexathia-18-crown-6-tetraone as membrane carrier was prepared. The influence of membrane composition, pH of test solution and foreign ions on the electrode performance were investigated. The electrode showed a Nernstian response over a lead concentration range from 1.0 x 10(-6) to 8.0 x 10(-3) M at 25 degrees C, and was found to be very sele...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید