نتایج جستجو برای: optic lens

تعداد نتایج: 94610  

2010
Nabeel A. Riza Philip J. Marraccini

To the best of our knowledge, proposed is the first liquid lens technology-based 1x2 fiber optic switch using a single Electronically Controlled Variable Focus Lens (ECVFL). By controlling the focal length of the liquid ECVFL, the input optical beam is spatially adjusted to couple into the respective output fiber port. The switch demonstrates a 3-dB bandwidth of 175.67 nm, with a center frequen...

Journal: :Investigative ophthalmology & visual science 1997
P Teesalu K Vihanninjoki P J Airaksinen A Tuulonen E Läärä

PURPOSE Visual field defects and changes in the optic nerve head are signs of glaucoma. It has been shown that blue-on-yellow (B-Y) perimetry can reveal visual field defects earlier and shows them larger than does white-on-white (W-W) perimetry. The Heidelberg retina tomograph (HRT) can produce three-dimensional images of the optic disc. The aim of this study was to find out how B-Y perimetry r...

Journal: :Experimental eye research 2000
J M Gad S L Keeling T Shu L J Richards H M Cooper

Recently it has been demonstrated that the guidance of retinal ganglion cell (rgc) axons through the optic disc is dependent on the DCC/netrin-1 axonal guidance system. To gain further insight into the function of the netrin receptors, DCC and Neogenin, in retinal development we have studied the expression patterns of these receptors in the embryonic mouse retina. Neogenin mRNA was restricted t...

Journal: :Experimental eye research 2004
Kurt O Gilliland Christopher D Freel Sonke Johnsen W Craig Fowler M Joseph Costello

PURPOSE To characterize multilamellar bodies (MLBs), determine their distribution along the optic axis and predict their potential Mie scattering within human age-related nuclear cataracts. Previous studies restricted to the equatorial plane have shown that MLBs are rare spherical objects that are 1-4 microm in diameter and covered by multiple layers of thin lipid-rich membranes. METHODS Eigh...

Journal: :Optics letters 2008
Reza Salem Mark A Foster Amy C Turner David F Geraghty Michal Lipson Alexander L Gaeta

We propose a new technique to realize an optical time lens for ultrafast temporal processing that is based on four-wave mixing in a silicon nanowaveguide. The demonstrated time lens produces more than 100 pi of phase shift, which is not readily achievable using electro-optic phase modulators. Using this method we demonstrate 20x magnification of a signal consisting of two 3 ps pulses, which all...

Journal: :Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft 2000
H Helbig R Rüesch

An 80-year-old man had intraoperative loss of an intraocular lens (IOL) in the vitreous and simultaneous implantation of an anterior chamber lens. For the first 3 years his course was uncomplicated, but after this time he noted monocular double vision. The IOL in the vitreous had moved into the optic axis of the eye. The case presented here underlines the possibility of complications occurring ...

Journal: :Postgraduate medical journal 1983
M A Spiteri D G James

Drugs acting on various parts of the body may also affect the eye insidiously. Increased awareness of such drug toxicity by the prescribing doctor should encourage him to consider effects on the cornea, lens, retina, optic nerve and elsewhere when checking the patient's progress. The following review concerns adverse ocular effects of systemic drug administration.

2013
D Schiano Lomoriello M Lombardo L Gualdi L Iacobelli L Tranchina P Ducoli S Serrao

PURPOSE To evaluate the position stability of a phakic intraocular lens (Cachet pIOL; Alcon, Laboratories, Inc., Fort Worth, TX) in the anterior chamber (AC) during a 6-months follow-up. METHODS Thirty eyes of 16 subjects underwent a Cachet pIOL implantation for the correction of high myopia from -6.50 to -16.00 D with plano targeted refraction. The position stability of the Cachet pIOL was e...

2004
N. Sujatha

This paper presents an all fiber optic endoscope system working in double modalities of normal imaging and fluorescence spectrum analysis, for the diagnosis of colon cancer. A coherent laser source is used here for providing the simultaneous illumination (for normal imaging mode) and excitation of fluorophores (for fluorescence spectrum analysis mode). The design aspects of the fiberscope dista...

2017
Mao Mao Márton Kiss Yvonne Ou Douglas B Gould

Ocular anterior segment dysgenesis (ASD) describes a spectrum of clinically and genetically heterogeneous congenital disorders affecting anterior structures that often lead to impaired vision. More importantly, 50-75% of patients with ASD develop early onset and aggressive glaucoma. Although several genes have been implicated in the etiology of ASD, the underlying mechanisms remain elusive. Typ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید