نتایج جستجو برای: osem reconstruction

تعداد نتایج: 123248  

2014
Florian Knoll Thomas Koesters Ricardo Otazo Tobias Block Li Feng Kathleen Vunckx David Faul Johan Nuyts Fernando Boada Daniel K Sodickson

Bernard & Irene Schwartz Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA State-of-the-art MR-PET scanners allow simultaneous data acquisition. However, image reconstruction is performed separately and results are only combined at the visualization stage. PET images are reconstructed using a variant of EM and MR data are reconstructed using...

2017
Livia Tossici-Bolt John C. Dickson Terez Sera Jan Booij Susanne Asenbaun-Nan Maria C. Bagnara Thierry Vander Borght Cathrine Jonsson Robin de Nijs Swen Hesse Pierre M. Koulibaly Umit O. Akdemir Michel Koole Klaus Tatsch Andrea Varrone

BACKGROUND [123I]FP-CIT is a well-established radiotracer for the diagnosis of dopaminergic degenerative disorders. The European Normal Control Database of DaTSCAN (ENC-DAT) of healthy controls has provided age and gender-specific reference values for the [123I]FP-CIT specific binding ratio (SBR) under optimised protocols for image acquisition and processing. Simpler reconstruction methods, how...

Journal: :Physics in medicine and biology 2004
A Rahmim M Lenox A J Reader C Michel Z Burbar T J Ruth V Sossi

We have investigated statistical list-mode reconstruction applicable to a depth-encoding high resolution research tomograph. An image non-negativity constraint has been employed in the reconstructions and is shown to effectively remove the overestimation bias introduced by the sinogram non-negativity constraint. We have furthermore implemented a convergent subsetized (CS) list-mode reconstructi...

2008
Bao-dong LIU Li ZENG Dong-jiang JI

The nondestructive testing (NDT) of long object (such as pipeline) has significant value. Computed tomography (CT) is able to generate 3D images and display the inner defects of the inspected object. Sometimes the long object fixed outdoors can’t be rotated, and the rotating of the X-ray source and detector is also difficult. So the linear scan CT, translating the X-ray source and detector alon...

2016
Marie-Odile Habert Sullivan Marie Hugo Bertin Moana Reynal Jean-Baptiste Martini Mamadou Diallo Aurélie Kas Régine Trébossen

BACKGROUND CATI is a French initiative launched in 2010 to handle the neuroimaging of a large cohort of subjects recruited for an Alzheimer's research program called MEMENTO. This paper presents our test protocol and results obtained for the 22 PET centres (overall 13 different scanners) involved in the MEMENTO cohort. We determined acquisition parameters using phantom experiments prior to pati...

Journal: :Hellenic journal of nuclear medicine 2013
Masato Kobayashi Hiroshi Wakabayashi Hironori Kojima Takahiro Konishi Koichi Okuda Hiroto Yoneyama Daiki Kayano Minoru Tobisaka Hiroyuki Tsushima Masahisa Onoguchi Keiichi Kawai Seigo Kinuya

Whole-body and single photon emission tomography (SPET) images during sodium iodide-131 (Na131I) ablation are useful to confirm the efficacy of ablation using 131I imaging. However, there have been no attempts to improve the quality of 131I imaging. We therefore investigated imaging protocols for 131I imaging in differentiated thyroid cancer (DTC). Phantoms containing 131I were used to simulate...

Journal: :EJNMMI physics 2014
Robin de Nijs Björn Neumann Jensen Jann Mortensen

Due to low counts in an (111)In single photon emission computed tomography (SPECT) scan, a large part of the head was missing in the reconstructed images on Philips Extended Brilliance Workspace (EBW) and IntelliSpace Portal (ISP) workstations. This problem occurred for the ordered subsets expectation maximization (OSEM) algorithm with and without resolution recovery (Astonish), but not for fil...

Journal: :Nuclear Medicine Communications 2013

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2001
G El Fakhri S C Moore P Maksud A Aurengo M F Kijewski

UNLABELLED Dual-isotope imaging can allow simultaneous assessment of brain perfusion using a 99mTc-labeled tracer and neurotransmission using an 123I-labeled tracer. However, the images are affected by scatter, cross talk, attenuation, distance-dependent collimator response (DCR), and partial-volume effect. We determined the accuracy and precision of activity quantitation in simulated normal an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید