نتایج جستجو برای: ozonation

تعداد نتایج: 1442  

Journal: :Water science and technology : a journal of the International Association on Water Pollution Research 2012
Nicolas Brodu Hicham Zaitan Marie-Hélène Manero Jean-Stéphane Pic

A hybrid process combining adsorption and ozonation was examined as an alternative treatment for odorous volatile organic compounds (VOCs). Methyl ethyl ketone (MEK) was chosen to study the influence of operating parameters. Two synthetic aluminosilicates (faujasite-Y and ZSM-5) were tested for adsorption and reactivity with ozone. The adsorption equilibrium measurement on both adsorbents showe...

2015
Zheng Cheng Rendang Yang Bin Wang Fei Yang

Heterogeneous Fe-Mn/sepiolite catalysts were prepared by the coprecipitation method, followed by heat treatment. The catalysts were characterized by several techniques; analysis by X-ray fluorescence (XRF) and scanning electron microscopy (SEM) confirmed the existence of fine Fe and Mn particles in the catalysts. Compared to natural sepiolite, the specific surface area of the Fe-Mn/sepiolite ca...

2000
U. von Gunten

The occurrence of Cryptosporidium in raw waters and bromate formation during ozonation of bromide-containing waters leads to a difficult optimisation of ozonation processes. On the one hand inactivation of Cryptosporidium requires high ozone exposures, on the other hand under these conditions bromate formation is favored. In order to overcome this problem we need information about (i) the oxida...

Journal: :Research report 1999
M W Frampton W A Pryor R Cueto C Cox P E Morrow M J Utell

We hypothesized that exposure of healthy humans to ozone at concentrations found in ambient air causes both ozonation and peroxidation of lipids in lung epithelial lining fluid. Smokers (12) and nonsmokers (15) were exposed once to air and twice to 0.22 ppm ozone for four hours with exercise in an environmental chamber; each exposure was separated by at least three weeks. Bronchoalveolar lavage...

Journal: :Journal of research in health sciences 2014
Mohammad Reza Samarghandi Seyed Alireza Babaee Mohammad Ahmadian Ghorban Asgari Farshid Ghorbani Shahna Ali Poormohammadi

BACKGROUND Toluene is a volatile organic compound, one of 189 hazardous air pollutants (HAPs) and the most important pollutant found in most industries and indoor environments; owing to its adverse health, toluene must be treated before being released into the environment. METHODS In this research study, a continuous-flow system (including an air compressor, silica gel filters and activated c...

Journal: :Cancer research 1979
G R Burleson M J Caulfield M Pollard

The Salmonella-microsome assay for mutagenesis was used to determine the effect of ozone on the mutagenesis of selected carcinogens and mutagens in water. Short periods of ozonation were shown to completely inactivate the mutagenicity of several polyaromatic amine mutagens including acriflavine, proflavine, and beta-naphthylamine. Selected polyaromatic hydrocarbons were also sensitive to ozonat...

Journal: :The American journal of physiology 1998
Edward M Postlethwait Rafael Cueto Leonard W Velsor William A Pryor

Recent evidence suggests that inhaled ozone (O3) does not induce toxicity via direct epithelial interactions. Reactions with epithelial lining fluid (ELF) constituents limit cellular contact and generate products, including lipid ozonation products, postulated to initiate pathophysiological cascades. To delineate specific aspects of lipid ozonation product formation and to estimate in situ surf...

Journal: :Water research 2013
Yaal Lester Hadas Mamane Ines Zucker Dror Avisar

Wastewater from a pharmaceutical formulation facility (TevaKS, Israel) was treated with a biological activated-sludge system followed by ozonation. The goal was to reduce the concentrations of the drugs carbamazepine (CBZ) and venlafaxine (VLX) before discharging the wastewater to the municipal wastewater treatment plant (WWTP). Both drugs were detected at extremely high concentrations in TevaK...

2003
F. Absi F. Gamache R. Gehr P. Liechti J. Nicell

An ozonation pilot plant was installed at the Montréal Urban Community Wastewater Treatment Plant (MUCWTP) to assess the feasibility of employing a full scale ozone disinfection system. Wastewater characteristics such as turbidity, COD, TOC, BOD, pH, ORP and suspended solids were monitored to assess their effect on ozone disinfection. Fecal conforms (FC) were used as indicators to measure disin...

Journal: :Chemical Engineering Journal 2022

Zeolite activation is the first, but often overlooked, post-synthetic treatment needed to transform an as-made material into adsorbent or catalyst. Ozonation at low temperatures provides alternative for conventional calcination treatments, with important consequences zeolite stability and acidity. While sometimes used in context of emptying novel less thermally stable structures, a thorough loo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید