The purpose of this research was to develop an applicable sampling and analytical method to determine airborne 4-vinyl-1-cyclohexene concentrations which are usually found in the atmosphere of polybutadiene factories. A solid sorbent tube, containing two sections (100 mg in the front and 50 mg in the back) of activated coconut-shell charcoal was chosen for sampling 4-vinyl-1-cyclohexene vapor. ...