نتایج جستجو برای: potentiometric determination

تعداد نتایج: 253339  

Journal: :Chemosensors 2021

A novel paper-based potentiometric platform for the simple and fast monitoring of water hardness is presented. First, ion-selective electrodes calcium magnesium printed on a paper substrate were built optimized. These sensors, which display near-Nernstian sensitivity, used determination concentration these cations calculation hardness. Second, incorporation solid-state reference electrode allow...

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaei masood giahi majjid arvand mehran aghaei

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

Journal: :journal of sciences islamic republic of iran 0

a carbon paste electrode modified with cobalt (ii) phthalocyanine (copc) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. the potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 m (?1- 1800 µg ml ) with a nernstian slope of 56 mv at ph 7. the limit of detection was 0.2 µg ml ascor...

A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...

Journal: :journal of physical & theoretical chemistry 2004
farrokh gharib karim zare ramin cheraghali

the dependence on ionic strength of protonation of l-aspartic acid and its complexation withdioxouranium(vi) is reported in sodium perchlorate solution as a background salt. the measurementshave been performed at 25 ± 0.1 °c and various ionic strengths in the range 0.1 to 1.0 mol dm-3, using acombination of potentiometric and spectrophotometric techniques. the overall analysis of the present an...

Farrokh Gharib Karim Zare, Ramin Cheraghali

The dependence on ionic strength of protonation of L-aspartic acid and its complexation withdioxouranium(VI) is reported in sodium perchlorate solution as a background salt. The measurementshave been performed at 25 ± 0.1 °C and various ionic strengths in the range 0.1 to 1.0 mol dm-3, using acombination of potentiometric and spectrophotometric techniques. The overall analysis of the present an...

   Significant effects of magnetic iron oxide (Fe3O4) nanoparticles on the potentiometric behavior of carbon paste electrode for bio determination of Isoniazid aromatic drug (INH) were studied. The electrochemical performance of modified Fe3O4/CPE was investigated. The constructed Fe3O4/CPE showed high precision, sensitivity ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2001
M Shamsipur M R Ganjali A Rouhollahi

A PVC-based membrane electrode for lead ions based on hexathia-18-crown-6-tetraone as membrane carrier was prepared. The influence of membrane composition, pH of test solution and foreign ions on the electrode performance were investigated. The electrode showed a Nernstian response over a lead concentration range from 1.0 x 10(-6) to 8.0 x 10(-3) M at 25 degrees C, and was found to be very sele...

Journal: :Journal of the American Chemical Society 2014
Xiaojiang Xie Jingying Zhai Eric Bakker

Potentiometric sensors require the implementation of conducting wires for signal transduction, but this is impractical for the readout of individual nanoparticles. It is here demonstrated for the first time that the potentiometric response of ion-selective nanospheres can be observed with voltage-sensitive dyes, thereby converting nanoscale electrochemical signals into an optical readout. No re...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید