Journal: :Physics in medicine and biology 2013
Bram L Gorissen Dick den Hertog Aswin L Hoffmann

Current inverse treatment planning methods that optimize both catheter positions and dwell times in prostate HDR brachytherapy use surrogate linear or quadratic objective functions that have no direct interpretation in terms of dose-volume histogram (DVH) criteria, do not result in an optimum or have long solution times. We decrease the solution time of the existing linear and quadratic dose-ba...

2007
Myonggeun Yoon Sung Yong Park Dongho Shin Se Byeong Lee Hong Ryull Pyo Dae Yong Kim Kwan Ho Cho

The goal of the present study was to develop a new dose-volume histogram (DVH)- based homogeneity index for effectively evaluating the dose homogeneity of intensity-modulated radiotherapy plans. The new index, called the sigma-index ("S-index") is defined as the standard deviation of the normalized differential DVH curve. In a study of 16 patients with brain tumors at our institution, the S-ind...

Journal: :Physics in medicine and biology 2008
Y Zinchenko T Craig H Keller T Terlaky M Sharpe

Radiation therapy is an important modality in treating various cancers. Various treatment planning and delivery technologies have emerged to support intensity modulated radiation therapy (IMRT), creating significant opportunities to advance this type of treatment. However, one of the fundamental questions in treatment planning and optimization, 'can we produce better treatment plans relying on ...

Journal: :Physics in medicine and biology 2004
Ying Xiao Darek Michalski Yair Censor James M Galvin

The efficient delivery of intensity modulated radiation therapy (IMRT) depends on finding optimized beam intensity patterns that produce dose distributions, which meet given constraints for the tumour as well as any critical organs to be spared. Many optimization algorithms that are used for beamlet-based inverse planning are susceptible to large variations of neighbouring intensities. Accurate...

Journal: :Stroke 1994
F Tracey R W Stout

There are two main reasons that this is not always so in practice. The first is that the skull also has considerable effects on the geometry of the ultrasound beam, varying from a simple shortening of the focal distance (due to refraction and refocusing) to complete disintegration of the sample volume caused by irregularities of the inner bony surface ("split beam"). The first of these may poss...

Journal: :Japanese Journal of Radiological Technology 1996

Journal: :Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology 2002
E Epstein L Skoog P-E Isberg F De Smet B De Moor P-A Olofsson S Gudmundsson L Valentin

OBJECTIVE To determine if power Doppler ultrasound examination of the endometrium can contribute to a correct diagnosis of endometrial malignancy in women with postmenopausal bleeding and endometrium > or = 5 mm. METHODS Eighty-three women with postmenopausal bleeding and endometrium > or = 5 mm underwent gray-scale and power Doppler ultrasound examination using predetermined, standardized se...