نتایج جستجو برای: saline contrast echo
تعداد نتایج: 465861 فیلتر نتایج به سال:
Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...
PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...
Idiopathic (primary) hyperhidrosis is defined as an excessive sweating with no clear cause and usually results in social, psychological, and professional disturbances. In this study, tap water and normal saline iontophoresis were used in a 21-year-old female suffering from severe idiopathic palmoplantar hyperhidrosis.The result of 8 sessions iontophoresis showed that tap water and norm...
BACKGROUND AND PURPOSE MR imaging has the potential capacity for noninvasively depicting the anatomy and function of thalamic nuclei. The purpose of this study was to identify the lateral geniculate nucleus (LGN), which is the thalamic relay nucleus for vision, with anatomic and functional MR imaging at 1.5 T. METHODS Three-millimeter-thick axial images were obtained from eight volunteers by ...
An interleaved gradient-echo echo-planar imaging (IGEPI) sequence was modified for and applied to dynamic contrast-enhanced imaging of the heart. Using IGEPI, images with 3.0 x 3.9 mm nominal in-plane resolution are acquired in 100 ms, enabling eight slices per heartbeat for a heart rate of 60 beats/min. The acquisition speed and use of saturation prepulses allows acquisition of short- and long...
BACKGROUND AND PURPOSE SWI is an MR technique conventionally implemented with single-echo gradient-echo data. The purpose of this study was to compare single-echo SWI processing and 2 multiecho SWI processing schemes: postaverage, where an SWI image is created for each echo and then averaged to create a single volume; and frequency-based, where a SWI image is generated from an average frequency...
Recently introduced 3D radial MRI pulse sequence entitled Multi-Band SWeep Imaging with Fourier Transformation (MB-SWIFT) having virtually zero acquisition delay was used to obtain functional MRI (fMRI) contrast in rat's brain at 9.4 T during deep brain stimulation (DBS). The results demonstrate that MB-SWIFT allows functional images free of susceptibility artifacts, and provides an excellent f...
We report the imaging of a patient in whom the diagnosis of acute pancreatitis and the assessment of disease severity was carried out using echo-enhanced ultrasonography. Contrast-enhanced computed tomography confirmed the echo-enhanced ultrasonography picture. Echo-enhanced ultrasonography may become the imaging technique of choice in assessing the severity of acute pancreatitis since it is ea...
PURPOSE To compare cardiac-triggered dual-echo spin-echo and magnetization transfer-prepared gradient-echo (MT-GE) MR imaging in the detection of multiple sclerosis (MS) lesions in the spinal cord. METHODS The cervical spinal cord in 20 patients with MS and in nine healthy volunteers was examined with spin-echo and MT-GE MR imaging. Sagittal images were scored for number of lesions, certainty...
MRI is very sensitive to detect bone metastases. To improve specificity, a clever use of sequences, spin echo, gradient echo in or opposed phase, contrast medium and diffusion is needed.
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید