نتایج جستجو برای: sick sinus syndrome

تعداد نتایج: 669144  

2014
Tanwier TTK Ramdjan Lisette JME van der Does Paul Knops Jan CJ Res Natasja MS de Groot

BACKGROUND The incidence of sick sinus syndrome will increase due to population ageing. Consequently, this will result in an increase in the number of pacemaker implantations. The atrial lead is usually implanted in the right atrial appendage, but this position may be ineffective for prevention of atrial fibrillation. It has been suggested that pacing distally in the coronary sinus might be mor...

Journal: :British heart journal 1986
R I Jones P M Cashman R S Hornung H Prince L Bassein E B Raftery

Ten patients in sinus rhythm with ventricular demand (VVI) pacemakers implanted for the sick sinus syndrome underwent 24 hour ambulatory blood pressure and electrocardiographic recording by a modified version of the Oxford system. Five patients had symptoms of dizziness or presyncope at the time of study and five were symptom free. The onset of pacing was associated with a fall in arterial bloo...

Journal: :Journal of Korean Medical Science 2003
Sedat Kose Atila Iyisoy Hurkan Kursaklioglu Ertan Demirtas

Electrical injury is a serious public health problem. Heart is one of the most frequently affected organs. Electrical injury can cause life-threatening cardiac complications such as asystole, ventricular fibrillation, and myocardial rupture. In this case report, we present a 20-yr-old male patient with sick sinus syndrome that developed years after electrical injury.

2005
LUDGER SEIPEL FRANZ LOOGEN

DISTURBANCES OF SINUS NODE AUTOMATICITY or of sinoatrial conduction or both have been assumed to occur in the sick sinus syndrome.' 6 A direct estimation of these parameters is not yet possible in man. Indirect methods have therefore been used for evaluation of sinus node function. Estimation of sinus node recovery time after overdrive suppression is a clinically useful method for evaluation of...

2005
LUDGER SEIPEL FRANZ LOOGEN

DISTURBANCES OF SINUS NODE AUTOMATICITY or of sinoatrial conduction or both have been assumed to occur in the sick sinus syndrome.' 6 A direct estimation of these parameters is not yet possible in man. Indirect methods have therefore been used for evaluation of sinus node function. Estimation of sinus node recovery time after overdrive suppression is a clinically useful method for evaluation of...

2015
Alexander Kypta Hermann Blessberger Michael Lichtenauer Thomas Lambert Juergen Kammler Clemens Steinwender

A 65-year-old man was scheduled for pacemaker implantation for symptomatic sick-sinus-syndrome (SSS). He suffered from multiple drug-allergies and allergies to several metals like quicksilver and titanium. Gold-coated pacemaker generators and polyurethane leads are effective in avoiding allergic reactions to pacing system components. Therefore, we decided to implant a custom-made gold-coated DD...

2011
Kakhaber Etsadashvili Haroon Mohammed Rashid Khatuna Jalabadze Anzor Melia

Congenital diaphragmatic hernia is very rare cause of AV block. We report such a patient with sick sinus node syndrome and previous AAIR pacemaker implantation, in which intermittent AV block was diagnosed by 24-hours ECG monitoring and upgrade of pacing system to DDDR was suggested.

Journal: :Circulation 2007
Halina Dobrzynski Mark R Boyett Robert H Anderson

Sick sinus syndrome is an abnormality involving the generation of the action potential by the sinus node and is characterized by an atrial rate inappropriate for physiological requirements. Manifestations include severe sinus bradycardia, sinus pauses or arrest, sinus node exit block, chronic atrial tachyarrhythmias, alternating periods of atrial bradyarrhythmias and tachyarrhythmias, and inapp...

2005
Elena B. Sgarbossa

Background. The goal of the report was to study the long-term incidence and the independent predictors for chronic atrial fibrillation and stroke in 507 paced patients with sick sinus syndrome, adjusting for differences in baseline clinical variables with multivariate analysis. Methods and Results. From 1980 to 1989, we implanted 376 dual-chamber, 19 atrial, and 112 ventricular pacemakers to tr...

Journal: :Circulation 1993
E B Sgarbossa S L Pinski J D Maloney T W Simmons B L Wilkoff L W Castle R G Trohman

BACKGROUND The goal of the report was to study the long-term incidence and the independent predictors for chronic atrial fibrillation and stroke in 507 paced patients with sick sinus syndrome, adjusting for differences in baseline clinical variables with multivariate analysis. METHODS AND RESULTS From 1980 to 1989, we implanted 376 dual-chamber, 19 atrial, and 112 ventricular pacemakers to tr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید