نتایج جستجو برای: surface contamination

تعداد نتایج: 681907  

2013
Haruyuki Ogino Takatoshi Hattori

This paper focuses on the surface contamination control of slightly contaminated property after the Fukushima nuclear accident. The operational level for the unconditional release of contaminated properties is calculated in counts per minute (cpm) to enable the use of a typical Geiger-Muller (GM) survey meter with a 50-mm bore, on the basis of the surficial clearance level of 10 Bq cm(-2) for (...

Journal: :Applied and environmental microbiology 1980
C J Thomas T A McMeekin

Scanning and transmission electron microscopy were used in conjunction with normal microbiological cultural techniques to examine some aspects of contamination of broiler carcass skin by bacteria during processing. The autochthonous skin microflora of poultry, before processing, was mainly Micrococcus spp. which were located in accumulations of sebum-like substances on the surface of the stratu...

Journal: :American journal of infection control 2010
David J Weber William A Rutala Melissa B Miller Kirk Huslage Emily Sickbert-Bennett

Health care-associated infections (HAI) remain a major cause of patient morbidity and mortality. Although the main source of nosocomial pathogens is likely the patient's endogenous flora, an estimated 20% to 40% of HAI have been attributed to cross infection via the hands of health care personnel, who have become contaminated from direct contact with the patient or indirectly by touching contam...

2013
Fangcheng Lv Chunxu Qin Yunpeng Liu Wenyi Guo Ruihai Li

This report describes the natural contamination test results of ±800kV line insulators at high altitudes. Natural exposure tests with -816kV DC voltage energization were carried out at National Engineering Laboratory for UHV Engineering Technology (Kunming).The results showed that the strain type and V-type insulator strings show a lighter pollution and the insulators with a better aerodynamic ...

Journal: :Applied and environmental microbiology 2003
R Montville D W Schaffner

Many factors have been shown to influence bacterial transfer between surfaces, including surface type, bacterial species, moisture level, pressure, and friction, but the effect of inoculum size on bacterial transfer has not yet been established. Bacterial cross contamination rates during performance of common food service tasks were previously determined in our laboratory using nalidixic acid-r...

1998
MARTIN J. BUTSON PETER K. N. YU PETER E. METCALFE

ÐMeasurement of lepton contamination is achieved across a radiotherapy photon beam and peripheral doses using radiochromic ®lm. An extrapolation technique is used where several layers are suspended in air to measure incident contamination without the e€ects of phantom scatter. Surface dose was measured as 11% of Dmax for 6 MV beams at central axis and 9% for 10 MV photons for a 10 10 cm ®eld si...

2010
Ellen Cristina de Carvalho Mendonça Samuel Nilo Vieira Fernando Aparecido Kawaguchi John Powers Adriana Bona Matos

OBJECTIVES To detect the influence of blood contamination (BC) on the bond strength (BS) of a self-etching bonding system (SES) to enamel and dentine. METHODS 25 human molars were longitudinally sectioned on the mesio-distal axis in order to obtain 50 specimens, which were embedded in acrylic resin. At first, the specimens were ground to expose a flat surface of enamel, and a bond strength te...

Journal: :Health physics 1999
S K Dua S K Biswas P Szerszen J Boudreaux M A Ebadian

Electret ion chambers are inexpensive, light-weight, commercially available, passive charge-integrating devices for accurate measurement of different radiations. Performance of electret ion chambers for surface alpha contamination measurement was evaluated. Ion chambers of two types and electrets of three thicknesses were used for the study. Calibration of the electret ion chambers was performe...

Journal: :Dental materials journal 2016
Taichen Lin Rie Kawamura Akira Aoki Shizuko Ichinose Koji Mizutani Yoichi Taniguchi Toru Eguro Norihito Saito Yuichi Izumi

Though the Er:YAG laser (ErL) has been used in periodontal therapy, the irradiated tip damage has not been studied in detail. In this study, the change in the energy output, surface morphology, and temperature of quartz tips was evaluated following contact irradiation. Soft tissue, calculus on extracted human teeth, and porcine bone were irradiated by ErL for 60 min at 14.2 or 28.3 J/cm(2)/puls...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید