نتایج جستجو برای: thenar
تعداد نتایج: 653 فیلتر نتایج به سال:
For three samples of material (12.5, 25.0 and 37.5 mm diameter) from each of three gloves, the dynamic stiffnesses and the vibration transmissibilities of the materials (to both the palm of the hand and the thenar eminence) were measured at frequencies from 10 to 300 Hz. Additional measurements showed the apparent masses of the hand at the palm and the thenar eminence were independent of contac...
In traumatic amputations in the upper extremities, replantation has been commonly attempted with high success rates. However, successful implies both maintenance of length and good functional outcomes restored hand. Since thumb accounts for 40% to 50% hand function, utmost priority is on salvage thumb. cases when not feasible, various efforts have made replace thumb, including pollicization ind...
of a dissertation at the University of Miami. Dissertation supervised by Assistant Professor Dejan Tepavac and Dr. Christine Thomas. No. of pages in text. (198) Involuntary electromyographic (EMG) activity has been recorded in the thenar (thumb) muscles of spinal cord injured (SCI) subjects for only short time periods (minutes), but it is unknown if this motor unit activity is ongoing. Longer d...
[Purpose] The aim of this study was to investigate the changes in spinal motor neuron excitability and autonomic nervous system activity during motor imagery of isometric thenar muscle activity at 10% and 50% maximal voluntary contraction (MVC). [Methods] The F-waves and low frequency/high frequency (LF/HF) ratio were recorded at rest, during motor imagery, and post-trial. For motor imagery tri...
Patients with Kallmann's syndrome show hypothalamic hypogonadism, hyposmia, and congenital mirror movements. As a correlate, a defect of gonadotropic neuron migration into the brain was recently detected. Considering abnormal outgrowth of neurons also as a possible substrate underlying mirror movements, we studied 3 patients and 2 asymptomatic female gene carriers from a kindred with proven lin...
OBJECTIVE To compare a small cellular clamshell phone with a traditional office phone in the development of discomfort and muscle fatigue over time during phone use. BACKGROUND Phone use involves low-level static exertions that may be influenced by phone design. Phone design and its interactions with anthropometry may change shoulder and hand postures assumed during use, which in turn may mod...
OBJECTIVE To compare the responses of noninvasively measured tissue oxygen saturation (StO2) and calculated muscle oxygen tension (PmO2) to standard hemodynamic variables for early detection of imminent hemodynamic instability during progressive central hypovolemia in humans. DESIGN Prospective study. SETTING Research laboratory. SUBJECTS Sixteen healthy human volunteers. INTERVENTIONS ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید