نتایج جستجو برای: through benson boiler

تعداد نتایج: 1356014  

2010
Jiangyin Huang Wei Lin

This work studies the identification and control of circulation fluidized bed (CFB) boilers. The CFB boiler under investigation shows strong nonlinearity due to big changes of steam load. A linear parameter varying (LPV) model is used to represent the process dynamics and used in control. The steam flow is used as the working-point variable (scheduling variable) of LPV model. Multivariable plan...

2016
Sagar Bhatt

The goal of this project is to develop an technique to measure the PM produced by a two-stage wood based boiler in an inexpensive manner while still preserving high degree of accuracy. The general idea involved in the process involves sampling of the exhaust gas using a vacuum pump. A filter paper with a permeability of 2μm is used to capture PM2.5 present in the exhaust. The sampled data is me...

Journal: :Computers & Chemical Engineering 2013
Flavio Manenti Davide Papasidero Alessio Frassoldati Giulia Bozzano Sauro Pierucci Eliseo Ranzi

The modeling of thermal reaction furnaces of Sulfur Recovery Units (SRUs) is a rather complex problem since it involves different modeling scales such as the kinetic/molecular scale, the reactor scale, and the chemical process scale. This work introduces the multi-scale modeling approach to characterize the kinetic and reaction engineering scales for the thermal section of SRUs, involving the r...

2009
P. N. BOYES

Recommendations for Boilers up to 250 psig Ca 0.40 2.50 Na. 0.46 2.17 CaO. 0.56 1. 79 NaOH. 0.80 1. 25 Ca(HC031. . 1. 62 0.617 Na 2C03 1. 06 0.943 CaSO. 1. 36 0.735 NaHC03 1. 68 0.60 CaCl2 1.11 0.901 Na 2SO•. 1.42 0.704 Mg . 0.24 4.17 NaCI 1.17 0.855 MgO 0.40 2.48 CO2 , 0.44 2.27 MgC03 • 0.84 1.19 C03 0.60 1. 67 Mg(HC03) 2 ' 1. 46 0.685 HC03 1. 22 0.82 MgSO•. 1. 20 0.833 SO•. 0.96 1.04 MgCl2 0....

2013
Jozef Jandačka Michal Holubčík Štefan Papučík Radovan Nosek

The alternative energy sources are more and more used for production of heat. Several new combustion devices allow co-firing of different fuels, like dendromass and phytomass. The article analyses combustion of wood and straw pellets in the same boiler. Measurements were realized in two automatic heat sources – one is adapted to burn pellets made from wood or straw and another allows only burni...

Journal: :IOP Conference Series: Earth and Environmental Science 2018

2014
Andrew D. Liston Guy T. Knight David A. Sheppard Gavin R. Broad Laurence Livermore

The superfamilies Cephoidea, Orussoidea, Pamphilioidea, Siricoidea, Tenthredinoidea, Xiphydrioidea and Xyeloidea are combined as one checklist section, as the sawflies represent a distinctive assemblage of phytophagous (except Orussidae) Hymenoptera. More than fifty years have passed since the publication of the final part of Robert B. Benson’s three part identification key to the “Symphyta” of...

ژورنال: حیات 2010
ذاکری‌مقدم, معصومه, شبان, مرضیه, مهران, عباس, هاشمی, سیما,

Background & Aim: Anxiety is a common experience which is felt as uneasiness, non-specific threat, and activation of autonomic nervous system. The aim of this study was to assess the effect of muscular relaxation on anxiety level of patients underwent cardiac catheterization. Methods & Materials: In this clinical trial, 118 patients who were expected to have a cardiac catheterization were recr...

2015
V. Pavithra Mary Jansi Rani Sri Ramakrishna

The water level of boiler drum is one of the crucial control parameters for any process industry which reflects the control of mainly boiler load and feed water indirectly. If the level exceeds the limits, boiler water carryover into the superheater or the turbine may cause damage resulting in extensive maintenance costs. If the level is low, overheating of the water wall tubes may cause tube r...

2010
Brian Solberg Palle Andersen Jan M. Maciejowski Jakob Stoustrup

This paper discusses optimal control strategies for switching between different burner modes in a novel compact marine boiler design. The ideal behaviour is defined in a performance index the minimisation of which defines an ideal trade-off between deviations in boiler pressure and water level from their respective setpoints and the cost of burner switches and variation of continuous input flow...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید