نتایج جستجو برای: ventricular septal occluder device endocarditis

تعداد نتایج: 845581  

Journal: :Journal of interventional cardiology 2009
Aysenur Pac Tugcin Bora Polat Ilker Cetin Mehmet Burhan Oflaz Sevket Balli

OBJECTIVES Occlutech Figulla ASD Occluder (FSO) is an alternative device to Amplatzer Septal Occluder (ASO) with some structural innovations including increased flexibility, minimizing the amount of material implanted, and absence of the left atrial clamp. We aimed to report our experiences with FSO and compare the outcomes of this novel device versus ASO. INTERVENTIONS Between December 2005 ...

Journal: :JACC. Cardiovascular interventions 2011
Israel M Barbash Christina E Saikus Anthony Z Faranesh Kanishka Ratnayaka Ozgur Kocaturk Marcus Y Chen Jamie A Bell Renu Virmani William H Schenke Michael S Hansen Michael C Slack Robert J Lederman

OBJECTIVES This study sought to evaluate feasibility of nonsurgical transthoracic catheter-based left ventricular (LV) access and closure. BACKGROUND Implanting large devices, such as mitral or aortic valve prostheses, into the heart requires surgical exposure and repair. Reliable percutaneous direct transthoracic LV access and closure would allow new nonsurgical therapeutic procedures. MET...

Journal: :Journal of Cardiothoracic Surgery 2008
Florian Loeffelbein Christian Schlensak Sven Dittrich

BACKGROUND To describe complications associated with Amplatzer septal occluders in a patient with Marfan syndrome CASE PRESENTATION A nine-year-old boy with Marfan syndrome and a 22 mm atrial septal defect (ASD) was treated successfully by interventional closure of his ASD by placing a 24 mm Amplatzer septal occluder. Follow up examinations showed a good result but an increasing enlargement o...

Journal: :Heart Rhythm 2023

Diastolic mitral regurgitation (DMR) may occur due to an increased left ventricular (LV) cavity pressure compared the atrial (LA) pressure. This with bradycardia when diastolic filling time is increased. In our case, patient was found have blocked bigeminal premature contractions (PACs) causing leading regurgitation. N/A A 58-year-old woman presented one week history of shortness breath, paroxy...

Journal: :Circulation 1989
J E Lock J J Rome R Davis S Van Praagh S B Perry R Van Praagh J F Keane

Recent experience with the spring-loaded patent ductus arteriosus (PDA) occluder has demonstrated several advantages of this device in the closure of intracardiac defects compared with previously described techniques. Pathologic and animal model studies were performed to identify which atrial septal defects (ASDs) might be suitable for device closure and to test a new septal closure double umbr...

Journal: :British heart journal 1983
J E Otterstad S Nitter-Hauge E Myhre

Clinical and haemodynamic findings were reviewed in 109 consecutive patients in whom an isolated ventricular septal defect was diagnosed after the age of 15 years (range 15-65 years). Most patients had no or minor cardiac symptoms. Based on the left to right shunt size and pulmonary pressure, 32 (29%) patients had large and 75 (69%) small ventricular septal defects, whereas in two (2%) patients...

نمودار تعداد نتایج جستجو در هر سال