نتایج جستجو برای: 3d dosimetry

تعداد نتایج: 196009  

Journal: :iranian journal of radiation research 0
t. allahverdi pourfallah department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran n. riyahi alam department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m.r. ay research center for science and technology in medicine, tehran university of medical sciences, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran

background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...

2009
L. Bibin J. Anquez A. Hadjem E. Angelini J. Wiart I. Bloch

Wireless systems are increasingly used and the electromagnetic fields (EMF) generated by these systems have induced a large public concern regarding potential sanitary effects, in particular on children and fetus during pregnancy. Few works have been performed to analyze the fetus exposure but additional studies are still needed, based on precise anatomical models. In this paper, we propose a n...

Journal: :Radiographics : a review publication of the Radiological Society of North America, Inc 2000
D B Downey A Fenster J C Williams

Three-dimensional (3D) ultrasonography (US) is rapidly gaining popularity as it moves out of the research environment and into the clinical setting. This modality offers several distinct advantages over conventional US, including 3D image reconstruction with a single pass of the US beam, virtually unlimited viewing perspectives; accurate assessment of long-term effects of treatment; and more ac...

H. Gharaati, H.R. Baghani, S.M. Hosseini Daghigh, S.M.R. Aghamiri, S.R. Mahdavi,

Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...

2001
Maria F. Chan Albert YC Fung Yu‐Chi Hu Chen‐Shou Chui Howard Amols Marco Zaider David Abramson

The BANG (MGS Research Inc., Guilford, CT) polymer gel has been used as a dosimeter to determine the three-dimensional (3D) dose distribution of a ruthenium-106 (Ru-106) ophthalmologic applicator. An eye phantom made of the BANG gel was irradiated with the Ru-106 source for up to 1 h. The phantom and a set of calibration vials were scanned simultaneously in a GE 1.5 T MR imager using the Hahn s...

2012
Julien Henriet Pierre-Emmanuel Leni Rémy Laurent Ana Roxin Brigitte Chebel-Morello Michel Salomon Jad Farah David Broggio Didier Franck Libor Makovicka

In case of a radiological emergency situation involving accidental human exposure, a dosimetry evaluation must be established as soon as possible. In most cases, this evaluation is based on numerical representations and models of subjects. Unfortunately, personalised and realistic human representations are often unavailable for the exposed subjects. However, accuracy of treatment depends on the...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید