نتایج جستجو برای: biodegradable alloy corrosion hydroxyapatite sputtering

تعداد نتایج: 108831  

, ,

    Nowadays, suitable protective properties of tantalum nitride coatings, such as hardness, abrasion resistance and high corrosion resistance lead to increasing its application in medical engineering and improving the biological behavior of titanium and its alloys. In this research, nanostructured tantalum nitride coating was applied on the NiTi alloy by magnetron sputtering method. Then, the ...

2013
Anna Hynowska Andreu Blanquer Eva Pellicer Jordina Fornell Santiago Suriñach Maria Dolors Baró Sergio González Elena Ibáñez Lleonard Barrios Carme Nogués Jordi Sort

The synthesis and characterization of Ti40Zr20Hf20Fe20 (atom %) alloy, in the form of rods (f = 2 mm), prepared by arc-melting, and subsequent Cu mold suction casting, is presented. The microstructure, mechanical and corrosion properties, as well as in vitro biocompatibility of this alloy, are investigated. This material consists of a mixture of several nanocrystalline phases. It exhibits excel...

Journal: :Metals 2021

A gradient Mg-8 wt % Si alloy, which was composed of the agglomerated Mg2Si crystals coating (GMS8-1) and eutectic Mg–Si alloy matrix (GMS8-2), designed for biodegradable orthopedic implant materials. The bio-corrosion behavior evaluated by electrochemical measurements immersion tests. results show that a significant improvement resistance achieved using as compared with traditional (MS8), shou...

Journal: :Dental materials journal 2006
Yoshinari Matono Masaharu Nakagawa Shigeki Matsuya Kunio Ishikawa Yoshihiro Terada

The corrosion behaviors of Ti, Ti-6Al-7Nb and Ti-6Al-4V alloys, and an experimentally produced Ti-0.5Pt alloy in 0.05% to 2.0% concentrations of Acidulated Phosphate Fluoride (APF) solutions (corresponding to 226 to 9,050 ppm fluoride at pH 3.5 or 3.6) were examined. While the corrosion of Ti, Ti-6Al-7Nb and Ti-6Al-4V alloys might occur easily even in a diluted 0.05% APF solution, dissolution o...

2016
Patchara Pripanapong Shota Kariya Tachai Luangvaranunt Junko Umeda Seiichiro Tsutsumi Makoto Takahashi Katsuyoshi Kondoh

Ti and solution treated Mg alloys such as AZ31B (ST), AZ61 (ST), AZ80 (ST) and AZ91 (ST) were successfully bonded at 475 °C by spark plasma sintering, which is a promising new method in welding field. The formation of Ti₃Al intermetallic compound was found to be an important factor in controlling the bonding strength and galvanic corrosion resistance of dissimilar materials. The maximum bonding...

2016
Yongqian Xu Lihua Zhan

The creep aging behaviors of retrogressed Al-Zn-Mg-Cu alloy were studied by uniaxial tensile creep tests at 140 ◦C. The effects of creep aging time and applied stress on microstructures and properties of the studied alloy were investigated by using transmission electron microscope (TEM), hardness, and corrosion resistance tests. Results show that the effects of the creep aging process on micros...

Journal: :Proceedings of the National Academy of Sciences of the United States of America 2016
Jee-Wook Lee Hyung-Seop Han Kyeong-Jin Han Jimin Park Hojeong Jeon Myoung-Ryul Ok Hyun-Kwang Seok Jae-Pyoung Ahn Kyung Eun Lee Dong-Ho Lee Seok-Jo Yang Sung-Youn Cho Pil-Ryung Cha Hoon Kwon Tae-Hyun Nam Jee Hye Lo Han Hyoung-Jin Rho Kang-Sik Lee Yu-Chan Kim Diego Mantovani

There has been a tremendous amount of research in the past decade to optimize the mechanical properties and degradation behavior of the biodegradable Mg alloy for orthopedic implant. Despite the feasibility of degrading implant, the lack of fundamental understanding about biocompatibility and underlying bone formation mechanism is currently limiting the use in clinical applications. Herein, we ...

Journal: :Materials 2021

Together, 316L steel, magnesium-alloy, Ni-Ti, titanium-alloy, and cobalt-alloy are commonly employed biomaterials for biomedical applications due to their excellent mechanical characteristics resistance corrosion, even though at times they can be incompatible with the body. This is attributed poor biofunction, whereby tend release contaminants from attenuated surfaces. Coating of surface theref...

2015
Duo Wu Xingyu Chen Tianchan Chen Chunmei Ding Wei Wu Jianshu Li

Implant materials need to be highly biocompatible to avoid inflammation in clinical practice. Although biodegradable polymeric implants can eliminate the need for a second surgical intervention to remove the implant materials, they may produce acidic degradation products in vivo and cause non-bacterial inflammation. Here we show the strategy of "substrate-anchored and degradation-sensitive coat...

2013
Shanmugasigamani Srinivasan PR Thangavelu K N Srinivasan M Selvam

Zinc nickel alloy was deposited from alkaline bath at a PH of 13-14 with the nickel percentage of 5-9% in our prior research. Present study dealt with the research on 10-12% of Nickel at a PH of 12-13 from Zinc – nickel alloy electrolyte and the remaining percentage of Zinc, required for corrosion resistant applications to be used for reliable alternative of cadmium. Hull cell studies was carri...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید