نتایج جستجو برای: diode detector
تعداد نتایج: 78175 فیلتر نتایج به سال:
A two-degrees-of-freedom scanned beam imaging system with large dynamic range and dynamic focusing is demonstrated. The laser diode, photo-detector and the optical components are integrated on a moving platform that is made of FR4 (Flame-Retardant 4), a common polymeric substrate used in printed circuit boards. A scan angle of 52 degrees is demonstrated at 60 Hz resonant frequency while the las...
To measure various components with nano-scale precision, a new high-precision touch-trigger probe using a single low-cost sensor for a micro-coordinate measuring machine (CMM) is presented in this paper. The sensor is composed of a laser diode, a plane mirror, a focusing lens, and a quadrant photo detector (QPD). The laser beam from the laser diode with an incident angle is reflected by the pla...
This paper is devoted to the current status of novel fully active 3D (three-dimensional) fine-grained scintillator detector SuperFGD as a main part near off-axis upgrade program for T2K experiment. The following important components related such electronics and mechanics, wavelength shifting (WLS) fibers, light emitting diode (LED) calibration system are also discussed here well detector’s futu...
The neutron spectrometer discussed here consists of a windowless PIN diode coupled with a polyethylene converter (thickness 1 mm). Neutrons are detected through the recoil-protons generated in the converter via elastic scattering. The response functions composing the response matrix for unfolding the spectra of energy Ed deposited in silicon by recoil-protons were determined analytically [1]. T...
The purpose was to study the dosimetric characteristics of the small diameter (≤ 10.0 mm) BrainLAB cones used for stereotactic radiosurgery (SRS) treatments in conjunction with a Varian Trilogy accelerator. Required accuracy and precision in dose delivery during SRS can be achieved only when the geometric and dosimetric characteristics of the small radiation fields is completely understood. Alt...
Introduction: Wedge filters are used in radiotherapy to modify photon beam and improve dose uniformity in the target volume. Determination of wedge dose distribution is important to improve treatment planning accuracy. The utilization of treatment planning software to obtain dose distribution is not always available. In this work an analytical model has been developed to calcu...
Relative absorbed-dose energy response correction R for different detector materials in water, PMMA and polystyrene phantoms are calculated using Monte Carlo-based EGSnrc code system for ¹²⁵I and ¹⁶⁹Yb brachytherapy sources. The values of R obtained for ¹²⁵I source are 1.41, 0.92, 3.97, 0.47, 8.32 and 1.10, respectively, for detector materials LiF, Li₂B₄O₇ , A1₂O₃, diamond, silicon diode and ai...
We report on the fabrication and characterization of solid-state thermal neutron detectors with detection areas up to 16 cm that require only a single preamplifier for data acquisition. These detectors consist of a honeycomb-like micro-structured Si diode with boron-10 filled deep holes. A continuous p–n junction formed over the entire surface of the microstructure helps to achieve a low leakag...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید
