نتایج جستجو برای: fetal dosimetry

تعداد نتایج: 95471  

Journal: :Physics in medicine and biology 2000
M J Butson R Elferink T Cheung P K Yu M Stokes K Y Quach P Metcalfe

Verification of calculated lung dose in an anthropomorphic phantom is performed using two dosimetry media. Dosimetry is complicated by factors such as variations in density at slice interfaces and appropriate position on CT scanning slice to accommodate these factors. Dose in lung for a 6 MV and 10 MV anterior-posterior field was calculated with a collapsed cone convolution method using an ADAC...

2013
M. Benabdesselam F. Mady S. Girard

This study analyses the thermally stimulated luminescence (TSL) or thermoluminescence glow curve between 300 and 773 K of germanium-doped silica optical fibre and finds a main glow peak at around 500 K with a characteristic spectral emission centred at 400 nm. Both features are particularly suitable for dosimetry. Thus, an investigation by the TSL technique of some first clinically relevant fea...

2013
M Oldham

A quality assurance method that utilizes 3D dosimetry and facilitates clinical interpretation Oldham Mark; Thomas Andrew; O'Daniel Jennifer; Juang Titania; Ibbott Geoffrey; Adamovics John; Kirkpatrick John P International journal of radiation oncology, biology, physics (2012), 84(2), 540-6. PURPOSE: To demonstrate a new three-dimensional (3D) quality assurance (QA) method that provides comprehe...

Journal: :Physics in medicine and biology 2000
T Samaras P Regli N Kuster

Reliable information on the heat distribution inside biological tissues is essential for the planning and optimization of experiments which aim to study the effects of non-ionizing radiation (NIR). In electrodynamics, the finite-difference time-domain (FDTD) technique has become the dominant technique for radiofrequency dosimetry. In order to obtain the electromagnetic field and heat distributi...

Journal: :Physics in medicine and biology 2006
M E Miquel K S Rhode P L Acher N D Macdougall J Blackall R P Gaston S Hegde S L Morris R Beaney C Deehan R Popert S F Keevil

Post-implantation dosimetry is an important element of permanent prostate brachytherapy. This process relies on accurate localization of implanted seeds relative to the surrounding organs. Localization is commonly achieved using CT images, which provide suboptimal prostate delineation. On MR images, conversely, prostate visualization is excellent but seed localization is imprecise due to distor...

Journal: :Radiation protection dosimetry 2005
K Faulkner P Ortiz-Lopez E Vano

Patient dosimetry is performed in radiology and interventional radiology to assess whether deterministic injuries may occur and to establish the risk of stochastic effects. A fundamental problem for patient dosimetry is that no single quantity can be used to accurately assess both the risk of stochastic effects and whether deterministic injuries will occur following a specific examination or pr...

2014
Mauro Valente Wladimir Molina José Vedelago

Radiation dosimetry by Fricke gel was largely used, generally focused and optimized for radiotherapy applications therefore involving relative high dose levels. Fricke gel dosimetry has several advantages, like dose rate and LET almost independence, 3D mapping, among other. This work presents a novel Fricke gel dosimeter optimized for low dose levels. Several chemical composition were studied v...

Journal: :Physics in medicine and biology 2011
I Mrčela T Bokulić J Izewska M Budanec A Fröbe Z Kusić

A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in ...

2008
M. F. Desrosiers J. M. Puhl S. L. Cooper

NIST developed the alanine dosimetry system in the early 1990s to replace radiochromic dye film dosimeters. Later in the decade the alanine system was firmly established as a transfer service for high-dose radiation dosimetry and an integral part of the internal calibration scheme supporting these services. Over the course of the last decade, routine monitoring of the system revealed a small bu...

Journal: :Journal of radiation research 2006
Kenichi Tanaka Satoru Endo Alexander Ivannikov Shin Toyoda Eldana Tieliewuhan Kassym Zhumadilov Chuzo Miyazawa Shinji Suga Kazuhide Kitagawa Masaharu Hoshi

The influence of X-ray baggage scanning on electron spin resonance (ESR) dosimetry studies around the Semipalatinsk Nuclear Test Site (SNTS) has been examined at Incheon Airport in Korea, which is a transfer point of the routes from Kazakhstan to Japan. Utilized dosimeters are Japanese human tooth enamel for ESR and glass dosimeters. The difference between the estimated doses with the X-ray sca...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید