نتایج جستجو برای: flow focusing

تعداد نتایج: 575702  

Journal: :Analytical chemistry 2005
Huanchun Cui Keisuke Horiuchi Prashanta Dutta Cornelius F Ivory

This paper reports the application of ampholyte-based isoelectric focusing in poly(dimethylsiloxane) (PDMS) using methylcellulose (MC) to reduce electroosmosis and peak drift. Although the characteristics of PDMS make it possible to fabricate microfluidic chips using soft lithography, unstable electroosmotic flow (EOF) and cathodic drift are significant problems when this medium is used. This p...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سیستان و بلوچستان - دانشکده مهندسی 1392

flow in natural river bends is a complex and turbulent phenomenon which affects the scour and sedimentations and causes an irregular bed topography on the bed. for the reason, the flow hydralics and the parameters which affect the flow to be studied and understand. in this study the effect of bed and wall roughness using the software fluent discussed in a sharp 90-degree flume bend with 40.3cm ...

Journal: :Nature communications 2014
Eugene J Lim Thomas J Ober Jon F Edd Salil P Desai Douglas Neal Ki Wan Bong Patrick S Doyle Gareth H McKinley Mehmet Toner

Controlled manipulation of particles from very large volumes of fluid at high throughput is critical for many biomedical, environmental and industrial applications. One promising approach is to use microfluidic technologies that rely on fluid inertia or elasticity to drive lateral migration of particles to stable equilibrium positions in a microchannel. Here, we report on a hydrodynamic approac...

2013
Yoshinori Takei Hidekazu Mimura

Ultraprecise optical elements are applied in advanced optical apparatus. Elastic emission machining (EEM) is one of the ultraprecision machining methods used to fabricate shapes with 0.1-nm accuracy. In this study, we proposed and experimentally tested the control of the shape of a stationary spot profile by introducing a focusing-flow state between the nozzle outlet and the workpiece surface i...

2010
Mansoor Nasir Lisa C. Shriver-Lake Joel P. Golden Frances S. Ligler

Hydrodynamic focusing was used to increase the sensitivity of an impedance-based biosensor. A modified T-junction channel allowed the focusing of conducting fluid from the top and sides by a non-conducting fluid from a single sheath stream. A 4-electrode impedance setup was used as it is less susceptible to electrode polarization at low signal frequencies. Impedance measurements performed befor...

2017
Dominik Oberthuer Juraj Knoška Max O. Wiedorn Kenneth R. Beyerlein David A. Bushnell Elena G. Kovaleva Michael Heymann Lars Gumprecht Richard A. Kirian Anton Barty Valerio Mariani Aleksandra Tolstikova Luigi Adriano Salah Awel Miriam Barthelmess Katerina Dörner P. Lourdu Xavier Oleksandr Yefanov Daniel R. James Garrett Nelson Dingjie Wang George Calvey Yujie Chen Andrea Schmidt Michael Szczepek Stefan Frielingsdorf Oliver Lenz Edward Snell Philip J. Robinson Božidar Šarler Grega Belšak Marjan Maček Fabian Wilde Andrew Aquila Sébastien Boutet Mengning Liang Mark S. Hunter Patrick Scheerer John D. Lipscomb Uwe Weierstall Roger D. Kornberg John C. H. Spence Lois Pollack Henry N. Chapman Saša Bajt

Serial femtosecond crystallography requires reliable and efficient delivery of fresh crystals across the beam of an X-ray free-electron laser over the course of an experiment. We introduce a double-flow focusing nozzle to meet this challenge, with significantly reduced sample consumption, while improving jet stability over previous generations of nozzles. We demonstrate its use to determine the...

Journal: :Optica 2014
Edward Haojiang Zhou Haowen Ruan Changhuei Yang Benjamin Judkewitz

Focusing light through scattering media has been a longstanding goal of biomedical optics. While wavefront shaping and optical time-reversal techniques can in principle be used to focus light across scattering media, achieving this within a scattering medium with a noninvasive and efficient reference beacon, or guide star, remains an important challenge. Here, we show optical time-reversal focu...

Journal: :international journal of civil engineering 0
golparvar fard m. hydro-structure and structure research center, college of civil engineering, iran university of science and technology, tehran 16844, iran yeganeh bakhtiary a. hydro-structure and structure research center, college of civil engineering, iran university of science and technology, tehran 16844, iran cheng l.

this paper presents a k- turbulence model for simulation of steady current and itsinduced vortex shedding caused by the presence of an offshore pipeline. performance of the modelaround a circular cylinder above a wall with gap to diameter ratios of 0.1, 0.35 and 0.5 underdifferent flow regimes with reynolds numbers of 1500, 2500 and 7000 is studied. the flow field iscomputed with solving the re...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید