Background/aim: To compare intraocular pressure (IOP) measurements taken by the Goldmann applanation tonometer, the Tono-Pen and the ocular blood flow pneumotonometer in eyes with varying central corneal thickness (CCT) due to penetrating keratoplasty (PK), keratoconus (KC), and Fuchs’ endothelial dystrophy (FED). Methods: IOP was measured with the Goldmann applanation tonometer, Tono-Pen XL, a...
PURPOSE To investigate the changes in Goldmann applanation tonometry (GAT) and Ocular Response Analyzer (ORA) measurements with corneal edema induced by contact lenses. METHODS Twenty-five healthy, normal subjects (age, 23 ± 2 years) had central corneal radius (CCR), ORA, GAT, and central corneal thickness (CCT) measurements performed in both eyes before a thick, soft hydrogel contact lens wa...
PURPOSE High intraocular pressure (IOP) is an important risk factor for a variety of pediatric ophthalmic conditions. The purpose of this study is to evaluate the feasibility, length of examination, and corneal epithelial damage induced by rebound tonometry (RBT) versus Goldmann applanation tonometry (GAT) in school children. METHODS Healthy children (n=57) participated in a randomized, trans...
PURPOSE To compare parameters of biomechanical response of the human cornea measured as corneal hysteresis (CH) and corneal resistance factor (CRF) in patients with diabetes mellitus and healthy control subjects. SETTING Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin, Israel. METHODS In the right eye of each participant, the CH, CRF, Goldmann-correlated intraocular press...
PURPOSE To assess the biomechanical properties of corneas in patients with normal tension glaucoma (NTG) and to compare them with those of patients with primary open-angle glaucoma (POAG), ocular hypertension (OHT), and normal controls (N). METHODS Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann intraocular pressure (IOPg), and corneal compensated IOP (IOPcc) were obtained ...
PURPOSE To investigate the test-retest variability of and factors associated with the corneal deformation response, and evaluate its impact on IOP measurement. METHODS Forty normal and 140 glaucoma suspect/glaucomatous eyes of 104 individuals were prospectively included for repeated measurements of corneal deformation response by an ultra-high-speed Scheimpflug camera, followed by corneal hys...
BACKGROUND To evaluate the ocular pulse amplitude (OPA) in patients with chronic non-arteritic anterior ischaemic optic neuropathy (NAION). METHODS This cross-sectional study comprised a study group of 30 eyes from 30 patients with NAION and a control group of 31 eyes from 31 age and gender-matched healthy subjects. Bilateral OPA was measured with dynamic contour tonometry (DCT) and was compa...
PURPOSE To establish a standard clinical procedure for measuring intraocular pressure (Po) with the contact lens tonometer (CLT), to demonstrate possibilities for analyzing ocular pulsation and performing ophthalmodynamometry. METHODS A reliable histogram-based analyzing system for determining Po is used. First, the ocular pressure was registered with the CLT method and compared with the Gold...
PURPOSE To determine the clinical efficacy of corneal elasticity (CE) measurements as an index of intra-ocular pressure(IOP). The considerable body of evidence linking elevated intra-ocular pressure (IOP) to glaucomatous conditions, points to the importance of the accurate and reliable measurement of IOP for diagnosis, prevention and post treatment assessments. Recently an applanation resonator...