A new special-purpose computed tomographic (CT) imaging system is described which produces images based on measurements of the low-angle (0-10 degrees) x-ray diffraction properties of an object. Low-angle scatter in the diagnostic x-ray energy range is dominated by coherent scatter, and the system uses first-generation CT geometry to acquire a diffraction pattern for each pencil beam. The patte...

2010
Oliver Díaz Mary Yip Jorge Cabello David R. Dance Kenneth C. Young Kevin Wells

This paper reports on a further development of an image simulation chain, and in particular, the inclusion of contrast degradation across an image using scatter to primary ratios calculated using Monte Carlo simulation. The Monte Carlo technique, using the Geant4 toolkit, has been implemented to model the scatter conditions when imaging the CDMAM phantom with commercial digital mammography. Obs...

2006
Bassel Kassas Firas Mourtada John L. Horton Richard G. Lane Thomas A. Buchholz Eric A. Strom

A recently introduced brachytherapy system for partial breast irradiation, MammoSite, consists of a balloon applicator filled with contrast solution and a catheter for insertion of an 192Ir high-dose-rate (HDR) source. In using this system, the treatment dose is typically prescribed to be delivered 1 cm from the balloon's surface. Most treatment-planning systems currently in use for brachythera...

Journal: :basic and clinical cancer research 0
mina salemi master student of physics, dept basic science, islamic azad university central tehran branch, tehran, iran hasan nedaei assistant professor, radiotherapy physics dept, cancer institute, tehran university of medical science, iran s gholami assistant professor, radiotherapy physics dept, cancer institute, tehran university of medical science, iran

background: the purpose of this study was to investigate the application of the monte carlo technique to calculate and analysis of dosimetric parameters for electron beams used in radiotherapy. this technique is based on statistical method and has a powerful role in different radiotherapy aspects. materials and methods: the simulated medical linear accelerator was the varian clinac 2100c. the e...

Journal: :Physics in medicine and biology 2006
C J Moore T E Marchant A M Amer

Cone beam CT (CBCT) using a zonal filter is introduced. The aims are reduced concomitant imaging dose to the patient, simultaneous control of body scatter for improved image quality in the tumour target zone and preserved set-up detail for radiotherapy. Aluminium transmission diaphragms added to the CBCT x-ray tube of the Elekta Synergytrade mark linear accelerator produced an unattenuated beam...

Journal: :Medical physics 2013
A Faught S Davidson S Kry J Fontenot C Etzel G Ibbott D Followill

PURPOSE To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. PURPOSE To commission a multiple-source Monte Carlo model of Elekta linear accelerator beams of nominal energies 6MV and 10MV. METHODS A three source, Monte Carlo model of Elekta 6 and 10MV therapeutic x-ray...

Journal: :Radiological physics and technology 2012
Masayoshi Mizuta Shigeru Sanada Hiroyuki Akazawa Toshifumi Kasai Shuji Abe Yasuhiro Ikeno Shigeki Mitou

Our purpose in this study was to establish a selection standard for anti-scatter grids for a direct conversion flat-panel detector (FPD) system. As indices for grid evaluation, we calculated the selectivity, Bucky factor, and the signal-to-noise ratio improvement factor (SIF) by measuring rates of scatter transmission, primary transmission, and total transmission (based on the digitally display...

Journal: :Journal of nuclear medicine technology 2008
Faraz Kalantari Hossein Rajabi Nahid Yaghoobi

UNLABELLED A poor signal-to-noise ratio attributable to a low injected dose of thallium and the presence of scattered photons are the major impediments in the use of thallium as an imaging agent. Thallium decays in a complicated way and emits photons in a wide range of energies (68-82 keV). To increase the ratios of primary photons to scatter photons (primary-to-scatter ratios) and possibly inc...

2017
Ninita Lindfors Henrik Lund Hans Johansson Annika Ekestubbe

Objectives The aim of this in vitro study was to evaluate how a deviation from the horizontal plane, affects the image quality in two different CBCT-devices. Methods A phantom head SK150 (RANDO, The Phantom Laboratory, Salem, NY, USA) was examined in two CBCT-units: Accuitomo 80 and Veraviewepocs 3D R100 (J. Morita Mfg. Corp. Kyoto, Japan). The phantom head was placed with the hard palate par...

Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...