نتایج جستجو برای: heart valve prosthesis

تعداد نتایج: 483515  

Journal: :Revista espanola de cardiologia 2008
Nobuaki Suzuki Shiro Yamachika Katsusuke Yano

A 56-year-old woman was urgently admitted following an episode of syncope. Fourteen years earlier, she had undergone implantation of a tricuspid prosthesis due to Ebstein anomaly, with congestive heart failure (NYHA class III) and severe tricuspid regurgitation. A mechanical prosthesis had been selected (31-mm Medtronic-Hall® valve; Medtronic Inc., Minneapolis, Minnesota, USA) because of its st...

Journal: :Heart 2000
W Keeble S M Cobbe

This case, involving a 74 year old man who underwent mitral valve and aortic valve replacements, provides detailed insight into the perioperative echocardiographic and haemodynamic changes occurring when a mitral valve prosthesis intermittently obstructs. It illustrates the early sequence of electromechanical dissociation which would lead to cardiac arrest should a tilting disc prosthesis be im...

Journal: :Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology 2004
Oğuz Taşdemir

OBJECTIVE Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardia...

2010
Maryam Esmaeilzadeh Ahmad Mirdamadi Mozhgan Parsaee Anita Sadeghpour Majid Maleki Hooman Bakhshandeh Abkenar

BACKGROUND The evaluation of prosthetic valves is very difficult with two-dimensional transthoracic echocardiography alone. Doppler and color flow imaging as well as transesophageal echocardiography are more reliable to detect prosthetic valve dysfunction. However, Doppler study sometimes tends to be misleading due to the load-depending characteristics of peak and mean pressure gradients. The p...

Journal: :Canadian Journal of Cardiology 2022

BackgroundThe historical trend towards the use of bioprosthetic aortic heart valves led to an increasing number valve failures. In patients at high-risk for re-operation, transcatheter valve-in-valve (ViV) has become alternative therapeutic option, but can be limited by risk coronary occlusion. The objective is develop a high-fidelity simulator based on 3D printing patient's specific cardiac an...

2015
Martin Andreas Stephanie Wallner Kurt Ruetzler Dominik Wiedemann Marek Ehrlich Georg Heinze Thomas Binder Anton Moritz Michael J. Hiesmayr Alfred Kocher Guenther Laufer

OBJECTIVES Outcome of aortic valve replacement may be influenced by the choice of bioprosthesis. Pericardial heart valves are described to have a favourable haemodynamic profile compared with porcine valves, although the clinical notability of this finding is still controversially debated. Herein, we compared the long-term results of two commonly implanted bioprosthesis at a single centre. ME...

Journal: :Biomechanics and modeling in mechanobiology 2012
X Y Luo B E Griffith X S Ma M Yin T J Wang C L Liang P N Watton G M Bernacca

We investigate the behaviour of a dynamic fluid-structure interaction model of a chorded polyurethane mitral valve prosthesis, focusing on the effects on valve dynamics of including descriptions of the bending stiffnesses of the valve leaflets and artificial chordae tendineae. Each of the chordae is attached at one end to the valve annulus and at the other to one of two chordal attachment point...

Journal: :European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery 2011
Jörg Kempfert Ardawan J Rastan Gerhard Schuler Axel Linke David Holzhey Arnaud van Linden Friedrich-W Mohr Thomas Walther

OBJECTIVE Trans-apical aortic valve implantation (TA-AVI) using the Edwards SAPIEN™ prosthesis has evolved to a routine procedure for selected high-risk elderly patients. In rare cases, misplacement of the SAPIEN™ valve (too low a position), dysfunction of the leaflets or perforation of the interventricular septum (ventricular septal defect, VSD) occurs and requires immediate implantation of a ...

2012
Jon C George

Aortic stenosis is one of the more commonly encountered disease processes in valvular heart disease, affecting over 300,000 people worldwide. Surgical replacement of the aortic valve has been the mainstay of therapy for decades; however, in certain patients with prohibitively high-risk comorbidities, surgery is not a viable option. The advent of transcatheter aortic valve replacement has come t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید