نتایج جستجو برای: heart valve prosthesis
تعداد نتایج: 483515 فیلتر نتایج به سال:
A 56-year-old woman was urgently admitted following an episode of syncope. Fourteen years earlier, she had undergone implantation of a tricuspid prosthesis due to Ebstein anomaly, with congestive heart failure (NYHA class III) and severe tricuspid regurgitation. A mechanical prosthesis had been selected (31-mm Medtronic-Hall® valve; Medtronic Inc., Minneapolis, Minnesota, USA) because of its st...
This case, involving a 74 year old man who underwent mitral valve and aortic valve replacements, provides detailed insight into the perioperative echocardiographic and haemodynamic changes occurring when a mitral valve prosthesis intermittently obstructs. It illustrates the early sequence of electromechanical dissociation which would lead to cardiac arrest should a tilting disc prosthesis be im...
OBJECTIVE Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardia...
BACKGROUND The evaluation of prosthetic valves is very difficult with two-dimensional transthoracic echocardiography alone. Doppler and color flow imaging as well as transesophageal echocardiography are more reliable to detect prosthetic valve dysfunction. However, Doppler study sometimes tends to be misleading due to the load-depending characteristics of peak and mean pressure gradients. The p...
BackgroundThe historical trend towards the use of bioprosthetic aortic heart valves led to an increasing number valve failures. In patients at high-risk for re-operation, transcatheter valve-in-valve (ViV) has become alternative therapeutic option, but can be limited by risk coronary occlusion. The objective is develop a high-fidelity simulator based on 3D printing patient's specific cardiac an...
OBJECTIVES Outcome of aortic valve replacement may be influenced by the choice of bioprosthesis. Pericardial heart valves are described to have a favourable haemodynamic profile compared with porcine valves, although the clinical notability of this finding is still controversially debated. Herein, we compared the long-term results of two commonly implanted bioprosthesis at a single centre. ME...
We investigate the behaviour of a dynamic fluid-structure interaction model of a chorded polyurethane mitral valve prosthesis, focusing on the effects on valve dynamics of including descriptions of the bending stiffnesses of the valve leaflets and artificial chordae tendineae. Each of the chordae is attached at one end to the valve annulus and at the other to one of two chordal attachment point...
OBJECTIVE Trans-apical aortic valve implantation (TA-AVI) using the Edwards SAPIEN™ prosthesis has evolved to a routine procedure for selected high-risk elderly patients. In rare cases, misplacement of the SAPIEN™ valve (too low a position), dysfunction of the leaflets or perforation of the interventricular septum (ventricular septal defect, VSD) occurs and requires immediate implantation of a ...
Aortic stenosis is one of the more commonly encountered disease processes in valvular heart disease, affecting over 300,000 people worldwide. Surgical replacement of the aortic valve has been the mainstay of therapy for decades; however, in certain patients with prohibitively high-risk comorbidities, surgery is not a viable option. The advent of transcatheter aortic valve replacement has come t...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید