نتایج جستجو برای: impedance tensor
تعداد نتایج: 78996 فیلتر نتایج به سال:
Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...
Let’s define the vertical impedance of an 8-mm gap chamber due to geometric variation as one unit of impedance with the symbol zu. Since the resistive wall impedance of an 8mm gap chamber is 0.3 zu [2], the total impedance of an 8-mm gap chamber is 1.3 zu. The geometric impedance of a 5-mm gap chamber is 3.09 zu, which we obtained using the known scaling in Eq. (1) derived in [1]. Including 1.2...
چکیده ندارد.
in this paper, the matsumoto metric with special ricci tensor has been investigated. it is proved that, if is ofpositive (negative) sectional curvature and f is of -parallel ricci curvature with constant killing 1-form ,then (m,f) is a riemannian einstein space. in fact, we generalize the riemannian result established by akbar-zadeh.
amonge other things we give sufficient and necessary conditions for the lau product of banachalgebras to be biflat or biprojective.
The purpose of this paper is to provide a new approach for detection using bio-impedance. This impedance is measured by the four-electrode method. As the impedance changes resulting from ankle, knee, and hip movements depend on electrode placement, we determined the optimal electrode configurations for these movements by searching for high correlation coefficients, large impedance changes, and ...
Four-terminal impedance meters based on pseudo-bridges yield unexpected uncertainties when using high-contact-impedance electrodes. Adding a front-end amplifier to the impedance meter and rearranging the connection of the meter terminals overcome the contact impedance problem. However, because the compensation provisions in the instrument are meant to compensate only impedance residuals of test...
Different types of charge storage mechanisms at unmodified graphite vs. glassy carbon electrodes in acid sulphate supporting solution containing potassium hexacyanoferrate (II) redox active electrolyte, have been revealed by electrochemical impedance spectroscopy and supported by cyclic voltammetry experiments. Reversible charge transfer of Fe(CN)6 redox reaction detected by assessment of CVs o...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید