background : evaluation of exposition to volatile organic compounds (voc) and compare urinary level of urinary biological exposure index in sweepers in west of iran . methods: this study was carried out on 40 street sweepers and 40 non-exposed as control group living in hamadan city, west of iran. voc was analyzed using gas chromatography equipped with a flame ionization detector (fid). the uri...
Using the CORSIKA shower simulation package, the spatial distribution of energy deposited by the shower in the atmosphere through ionization is obtained and the distribution of light arriving to the detector is calculated. The resulting shower image is compared with that obtained using the NKG distribution of particles in the shower and a constant fluorescence yield. Taking into account the dis...
PURPOSE The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The...
We describe a modified gas-chromatographic method for acetate in serum or plasma, intended for use in the investigation of acetate intolerance in hemodialysis patients. The assay may be adapted for use with a single-column gas chromatograph equipped with a flame ionization detector. The analysis, made isothermally, requires only 0.5 ml of plasma or serum. Only one deproteinizing step is require...
The multiple ionization and fragmentation of acetylene was studied in collisions with 3.6 MeV/u Xe ions provided by the UNILAC at GSI. The fragmentation dynamics was studied using a positionand time-sensitive multiparticle detector [1] which allows the coincident measurement of the momenta of correlated fragment ions. If all fragment ions from a particular fragmentation are detected, a kinemati...
When in vivo proton dosimetry is performed with a metal-oxide semiconductor field-effect transistor (MOSFET) detector, the response of the detector depends strongly on the linear energy transfer. The present study reports a practical method to correct the MOSFET response for linear energy transfer dependence by using a simplified Monte Carlo dose calculation method (SMC). A depth-output curve f...
Submit Manuscript | http://medcraveonline.com Abbreviations: GLPs: Gracilaria Lemaneiformis Polysaccharides; FTIR: Fourier Transform Infrared Spectroscopy; GC: Gas Chromatography; HPGPC: High Performance Gel Permeation Chromatography; NK: Natural Killer; IL-2: Interleukin-2; IFN-γ: Interferon-γ; TNF-α: Tumor Necrosis Factor-α; BRM: Biological Response Modifier; ConA: Concanavalin A; LPS: Lipo P...
Adsorbent tube samples are collected by drawing workplace air through either coconut shell charcoal or Anasorb 747 tubes with personal sampling pumps. Diffusive samples are collected by exposing either 3M 3520 Organic Vapor Monitors (OVMs) or SKC 575-002 Passive Samplers to workplace air. Samples are desorbed with 60/40 (v/v) N,N-dimethylformamide/carbon disulfide (DMF/CS2) and analyzed by gas ...