PURPOSE Portal dose images acquired with an amorphous silicon electronic portal imaging device (EPID) suffer from artifacts related to backscattered radiation. The backscatter signal varies as a function of field size (FS) and location on the EPID. Most current portal dosimetry algorithms fail to account for the FS dependence. The ramifications of this omission are investigated and solutions fo...

D. Shahbazi-Gahrouei, M. Hosseinpour, M.B. Tavakoli,

Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...

2008
Valeri E. Galtsev E. V. Galtseva Ya.S. Lebedev

A new method for tooth (enamel and dentine) and bone EPR dosimetry is proposed that enhances substantially the dosimetric sensitivity. The method is based on the nonstandard spectra registration mode (the second harmonic phase quadrature detection of absorption under rapid passage conditions). This method provides an apparent enhancement of the component ratio of radiation to a nonradiative bac...

2015
Bree R. Eaton Shannon M. MacDonald Torunn I. Yock Nancy J. Tarbell

Radiation-induced secondary malignancies are a significant, yet uncommon cause of morbidity and mortality among cancer survivors. Secondary malignancy risk is dependent upon multiple factors including patient age, the biological and genetic predisposition of the individual, the volume and location of tissue irradiated, and the dose of radiation received. Proton therapy (PRT) is an advanced part...

2014
Iori Sumida Hajime Yamaguchi Hisao Kizaki Keiko Aboshi Yuji Yamada Yasuo Yoshioka Kazuhiko Ogawa

Dose verifications for intensity-modulated radiation therapy (IMRT) are generally performed once before treatment. A 39-fraction treatment course for prostate cancer delivers a dose prescription of 78 Gy in eight weeks. Any changes in multileaf collimator leaf position over the treatment course may affect the dosimetry. To evaluate the magnitude of deviations from the predicted dose over an ent...

2010
Vladimir Feygelman Geoffrey Zhang Craig Stevens

We performed an initial dosimetric evaluation of SmartArc - a novel VMAT planning module for Philips Pinnacle treatment planning system. A test suite of structure sets and dose objectives provided by the AAPM for multi-institutional comparison of IMRT dosimetry was used. A total of fifty plans were successfully delivered. The effect of control point spacing on dosimetric accuracy was investigat...

2016
Indra J. Das Chee-Wai Cheng Minsong Cao Peter A. S. Johnstone

Modern treatment planning systems provide accurate dosimetry in heterogeneous media (such as a patient' body) with the help of tissue characterization based on computed tomography (CT) number. However, CT number depends on the type of scanner, tube voltage, field of view (FOV), reconstruction algorithm including artifact reduction and processing filters. The impact of these parameters on CT to ...

Journal: :Clinical cancer research : an official journal of the American Association for Cancer Research 1997
K R Lamborn G L DeNardo S J DeNardo D S Goldstein S Shen E C Larkin L A Kroger

This study was designed to evaluate dosimetric, pharmacokinetic, and other treatment-related parameters as predictors of outcome in patients with advanced B-lymphocytic malignancies. Fifty-seven patients were treated with radiolabeled Lym-1 antibody in early phase trials between 1985 and 1994. Logistic regression and proportional hazards models were used to evaluate treatment parameters for the...

Journal: :IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII KHIMIYA KHIMICHESKAYA TEKHNOLOGIYA 2019

Journal: :Medical physics 2002
M Bucciolini S Russo F Banci Buonamici S Pini P Silli

A 6 MV photon beam from Linac SL75-5 has been collimated with a new micromultileaf device that is able to shape the field in the two orthogonal directions with four banks of leaves. This is the first clinical installation of the collimator and in this paper the dosimetric characterization of the system is reported. The dosimetric parameters required by the treatment planning system used for the...