نتایج جستجو برای: measurement uncertainty
تعداد نتایج: 553682 فیلتر نتایج به سال:
Two-Thickness-Method (TTM) based on an open-ended coaxial probe was investigated with an emphasis on uncertainty analysis to perfect this technique. Uncertainty equations in differential forms are established for the simultaneous measurement of complex electromagnetic (EM) parameters in the systematical consideration of various error factors in measurement. Worst-case differential uncertainty e...
Misinterpretation of uncertainty in the measurement of the electromagnetic field (EMF) strength may lead to an underestimation of exposure risk or an overestimation of required measurements. The Guide to the Expression of Uncertainty in Measurement (GUM) has internationally been adopted as a de facto standard for uncertainty assessment. However, analyses under such an approach commonly assume u...
Nutrient budgets for forested ecosystems have rarely included error analysis, in spite of the importance of uncertainty to interpretation and extrapolation of the results. Uncertainty derives from natural spatial and temporal variation and also from knowledge uncertainty in measurement and models. For example, when estimating forest biomass, researchers commonly report sampling uncertainty but ...
The aim of this paper is robust identification of smart foam, as an electroacoustic transducer, considering unmodeled dynamics due to nonlinearities in behaviour at low frequencies and measurement noise at high frequencies as existent uncertainties. Set membership estimation combined with model error modelling technique is used where the approach is based on worst case scenario with unknown but...
This document provides specifications of software units for the evaluation of measurement uncertainty. It is intended to align with and support established guides and extend their functionality in a consistent manner. It is also intended to complement the best-practice guide to uncertainty evaluation that has been produced as part of the UK Department of Industry’s National Measurement System S...
Presented is an analysis of the expanded uncertainty of an indirect measurement of modal birefringence of polarization maintaining fibers, based on the Sagnac interferometer and an optical spectrum analyzer. By using this method it is easy to achieve an expanded measurement uncertainty considerably lower than 1%, at a confidence level of 0.95, in measurements of fibers, whose birefringence is i...
Confidence of Measurement Methods and Results. Evaluation and Expression of Measurement Uncertainty.
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید