نتایج جستجو برای: outdoor dose rate
تعداد نتایج: 1245577 فیلتر نتایج به سال:
Abstract A comprehensive radiological survey was carried out in an open-cut slate stone quarry. The activity of 226 Ra, 228 Ra and 40 K the ore samples were measured as 38 ± 5, 41 6 869 52 Bq kg 1 , respectively. Outdoor radon indoor concentrations from 37 7 to 193 11 m ?3 (77 8 ), 49 253 23 (131 13 average outdoor gamma dose 116 84 nSv h ? annual effective doses estimated between 1.0 0.1 3.3 0...
The majority of diseases caused by air pollution, such as asthma and allergies, are caused by pathogenic bacteria, which are transmitted through bioaerosols. Bacteria and fungi are the main sources of hospital infections causing the majority of diseases and cases of mortality. The aim of this study was to determine the ratio of indoor to outdoor fungi concentration, the effect of population den...
Background: Best dose distribution in target volume and control of Organ at Risk (OAR) dose are the two main goals in brachytherapy. Materials and Methods: In this study in vivo dosimetry in 4 rectal points was performed by Transillumination Dosimeter (TLD) s and the measured doses were compared in different patients. One point was reported to have the maximum dose in each patient and the very ...
Models for human perception of thermal environments included in so-called thermal comfort standards are either based on principles of thermal heat balance, or on large empirical datasets that include human adaptations to different thermal environments (i.e. so-called adaptive approach). The framework for an adaptive thermal heat balance model (ATHB) combines these 2 approaches, improves the pre...
Interstitial brachytherapy represents the treatment of choice for small tumours, regionally localized in the oral cavity and the oropharynx. In the technical setting, continuous low-dose-rate (LDR) brachytherapy represented for many years the gold standard for administering radiation in head and neck brachytherapy. Large series of head and neck cancer patients treated with LDR brachytherapy hav...
The capability of the TrueBeam treatment system to deliver step and shoot IMRT plans at low dose rates was evaluated. Beam characteristics during low dose rates (5 to 100 MU/min) were evaluated for consistency using a planar ion chamber array. MU constancy, linearity, and beam profile symmetry were all found to be equivalent within 0.5%. The response of the Scandi Dos Delta 4 system was also ev...
BACKGROUND AND PURPOSE Theoretical calculations suggest that pulsed dose-rate irradiation (PDR) should have approximately the same effectiveness as continuous low dose-rate (CLDR) when the same total dose is given in the same overall time, unless large doses per pulse (> 2 Gy) are used and/or non-exponential or very short half-times of repair (< 0.5 h) are present in the irradiated tissues. How...
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
background: heat stress evaluation and timely notification, especially using meteorological data is an important issue attracted attention in recent years. therefore, this study aimed at answering the following research questions: 1) can enthalpy as a common environmental parameter reported by meteorological agencies be applied accurately for evaluation of thermal condition of outdoor settings,...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید