Background and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT) and computed tomography (CT).Materials and Methods: Thermoluminescent dosimeters (TLD) were implanted in 14 sites of RANDO phantom to measu...

Introduction: Radiation therapy planning (RTP) is one of the clinical applications in which both CT scan and MRI are used. MR and CT images are applied to determine the target volume and calculation of dose distribution, respectively. In addition, using two imaging modalities increases the department workload and cost. In this study, an algorithm was presented to create synthet...

A. Saravanakumar, B. Devanand, K. Vaideki, K.N. Govindarajan, S. Jayakumar, S.D. Sharma,

Background: To suggest South India CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations. Materials and Methods: A pilot study investigated the most frequent CT examinations. 110 CT sites were asked to complete a survey booklet to allow the recording of CT parameters for each of 3 CT examinations during a 1 year time period. Dose...

Z Adwan

In a patient with features indicating the presence of pseudotumor cerebri, a negative cranial CT-scan is not adequate to rule out less benign pathology and an MRI of brain should be performed. In this study, a 10-year old boy with daily headaches for one month and diplopia for one week was found to have a partial abducens palsy and bilateral papilledema; otherwise, his examination was normal. A...

Journal: :archives of breast cancer 0
mahdi aghili department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran parisa seifi department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran farshid farhan department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran ahmad reza sebzari department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran ehsan mohamadi department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran vahid vaezzadeh department of radiation oncology, radiation oncology research center, cancer institute, tehran university of medical sciences, tehran, iran

background: the axillary and supraclavicular nodal volume treatment results in improvement of local control and survival after breast conserving surgery (bcs) or modified radical mastectomy (mrm). studies on the depth of these nodes have questioned the consistent use of standard fields for all patients. this study was done to assess the dose delivery to these lymph nodes with conventional treat...

Ghorban Safaeian, Mina Nouri, Mohammad Hosein Bahreyni Toossi Mohammad Taghi Bahreyni Toossi Shahram Bayani

Introduction: The objective of this work is to study the ability of MRI normoxic polymer gel dosimetry system to be used to verify the calculated dose distribution, in a simple geometry, in clinical radiotherapy. Materials and Methods:  Initially, 2 liters of the normoxic MAGAT polymer gel was prepared and then poured into two cylindrical Perspex phantom (simu...

Ahmad Mostaar, Mohammad Houshyari Zeinab Sattari

Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...

Journal: :iranian journal of science and technology (sciences) 2015
m. mahdavi

computed tomographyrepresents about 10% of all diagnostic radiology procedures, but it isresponsible for almost 50% - 60% of exposure from diagnostic procedures. inhead ct, other critical organs such as eye lenses and thyroids are in theradiation field. therefore, dose assessment in these organs is very important.the aim of this study is to estimate the absorbed dose in critical organs ofpatien...

Journal: :Medical physics 2017
Francesco Ria Joshua Mark Wilson Yakun Zhang Ehsan Samei

PURPOSE Modern CT systems adjust X-ray flux accommodating for patient size to achieve certain image noise values. The effectiveness of this adaptation is an important aspect of CT performance and should ideally be characterized in the context of real patient cases. The objective of this study was to characterize CT performance with a new metric that includes image noise and radiation dose acros...