نتایج جستجو برای: percentage depth dose

تعداد نتایج: 592179  

2016
Ambreen Aslam Muhammad Basim Kakakhel Shaukat Ali Shahid Lubna Younas Sobia Zareen

In this work, soft-tissue equivalence of water, polystyrene, PMMA and water equivalence of polystyrene, and PMMA has been assessed for multiple megavoltage photon beams and field sizes. EGSnrc based Monte Carlo (MC) codes, BEAMnrc and DOSXYZnrc are used for the linac head modeling and the phantom dose calculations, respectively. Percentage depth doses (PDDs) are scored for two field sizes (5 × ...

Journal: :iranian journal of radiation research 0
s.h. mousavie anijdan department of medical physics and engineering, school of medicine, tehran university of medical sciences, tehran, iran a. shirazi department of medical physics and engineering, school of medicine, tehran university of medical sciences, tehran, iran s.r. mahdavi department of medical physics and engineering, school of medicine, tehran university of medical sciences, tehran, iran a. ezzati department of energy engineering, sharif university of technology, tehran, iran b. mofid department of radiation oncology, shahid beheshti university of medical sciences, tehran, iran s. khoei department of medical physics and engineering, school of medicine, tehran university of medical sciences, tehran, iran

background: gold nanoparticles (gnps) have been shown as a good radiosensitizer. in combination with radiotherapy, several studies with orthovoltage x-rays have shown considerable dose enhancement effects. this paper reports the dose enhancement factor (def) due to gnps in 18 megavoltage (mv) beams. materials and methods: different geometrical 50-nm gnps configurations at a concentration of 5 m...

2015
Francisco Clemente‐Gutiérrez Consuelo Pérez‐Vara

A pretreatment quality assurance program for volumetric techniques should include redundant calculations and measurement-based verifications. The patient-specific quality assurance process must be based in clinically relevant metrics. The aim of this study was to show the commission, clinical implementation, and comparison of two systems that allow performing a 3D redundant dose calculation. In...

2014
Teresa Garcia-Martinez Jan-Pieter Chan Jose Perez-Calatayud Facundo Ballester

PURPOSE Brachytherapy with radioactive high dose rate (HDR) (192)Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachythera...

2015
Bongsoo Lee Guwon Kwon Sang Hun Shin Jae Seok Kim Wook Jae Yoo Young Hoon Ji Kyoung Won Jang

In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide...

Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...

F. Rahmani, H Khalafi, S.M. Abtahi, S.M.R. Aghamiri,

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

Journal: :Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 2011
Sathiyan Saminathan Ravikumar Manickam Sanjay S Supe

BACKGROUND Wedge filters can be used as missing tissue compensators or wedge pairs to alter the shape of isodose curves so that two beams can be angled with a small hinge angle at a target volume without creating a hotspot. AIM In this study the dosimetric properties of Varian Enhanced Dynamic Wedge (EDW) and physical wedges (PW) were analyzed and compared. MATERIALS AND METHODS Ionometric ...

Journal: :Journal of animal science 2010
A P Schinckel J R Wagner J C Forrest M E Einstein

The accuracy of 3 optical probes (HGP4 Hennessey Grading Probe, Destron-Feering PG-100 probe, and Giraldo OPTO-Electronic PG-200 probe) to predict the carcass percentage of 5 alternative measures of carcass composition (fat-tissue-free lean, lipid-free soft tissue, lipid-free lean, total fat tissue, and soft tissue lipid) was evaluated on 203 barrows and gilts of 7 genetic populations. The opti...

Farnaz Rahimli hamideh mazraeh Mahbube Fadaei Mansour Zabihzadeh Mojtaba Hoseini- Ghahfarokhi Seyed Mohammad Hoseini Sholeh Arvandi

Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید