نتایج جستجو برای: percutaneous screw fixation
تعداد نتایج: 117537 فیلتر نتایج به سال:
Problems that screw cannot be inserted may occur in screw-rod fixation techniques such as Harms technique. We compared the biomechanical stability imparted to the C-2 vertebrae by four designed posterior screw and rod fixation techniques for the management of odontoid fractures. A three-dimensional finite element model of the odontoid fracture was established by subtracting several unit structu...
Background & Aims: Thuracolumbar Unstable Fractures (T, L.U.F) are common after spine truma. Posterior pedicular fixation is a technique that is use for fixation of these fractures. This study evaluates the accuracy of pedicular screw placement in T, LUF with the assistance of plain radiography in operation rooms. Materials & Methods: This study is a case-control and analytical study. 35 pa...
OBJECTIVE The objective of this prospective study was to test whether the treatment of Lisfranc injuries with open reduction and dorsal plate fixation would have the same or better functional outcomes as treatment with standard trans-articular screw fixation. METHODS Sixty patients with primarily isolated Lisfranc joint injury were treated by open reduction and dorsal plate fixation or standa...
Division of Orthopedic Surgery, Department of Surgery, Far Eastern Memorial Hospital; and Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei. Received: 28 October 1999. Revised: 26 November 1999. Accepted: 1 February 2000. Reprint requests and correspondence to: Dr. Sheng-Mou Hou, Department of Orthopedic Surgery, National Taiwan University Hospital, 7 Chung-Shan Sout...
abstract background: distal radial fracture is one of the most common fractures of the skeletal system. although it has been believed to be a simple fracture with excellent outcomes, practical operations’ results have always been undesirable and even poor. the goal of this study was to compare two methods of treatment “pin and plaster and precautious pin fixation in patients with unstable extra...
PURPOSE To compare the outcome following headless compression screw fixation versus radial head arthroplasty versus plate fixation for 3-part Mason types III or IV radial head fracture. METHODS Records of 25 men and 16 women aged 21 to 80 (mean, 43.3) years who underwent fixation using 2 to 3 2-mm cannulated headless compression screws (n=16), radial head arthroplasty (n=13), or fixation with...
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
In situ stabilization remains the standard of care in the treatment of stable slipped capital femoral epiphysis (SCFE). Screw placement perpendicular to the physis has shown satisfactory results with minimal complications. A prominent screw head may produce femoral acetabular impingement and pain after in situ fixation in severe SCFE. We performed a biomechanical study to establish whether scre...
BACKGROUND The acetabular component has remained the weakest link in hip arthroplasty regarding achievement of long-term survival. Primary fixation is a prerequisite for long-term performance. For this reason, we investigated the stability of a unique cementless titanium-coated elastic monoblock socket and the influence of supplementary screw fixation. PATIENT AND METHODS During 2006-2008, we...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید