نتایج جستجو برای: polymer gel treatment

تعداد نتایج: 1570732  

1996
M.J.E. Richardson

We study the motion of long polymers (eg DNA) in a gel under the influence of an external force acting locally on small segments of the polymer. In particular, we examine the dependence of the drift velocity on the position where the force acts and the length of the polymer. As an application, we discuss the possibility of gel magnetophoresis the size-separation of long polymers by the attachme...

2017
Wangyu Li Ying Pang Jingyuan Liu Guanghui Liu Yonggang Wang

A lithium-ion conducting gel polymer electrolyte (GPE) membrane containing PEO as a polymer host and liquid electrolyte has been prepared by a simple one-step procedure. The prepared electrolyte membrane exhibits a good ionic conductivity of 3.3 10 3 S cm 1 and high lithium transference number of 0.76 at room temperature. Meanwhile, the gel polymer electrolyte membrane shows very good thermal s...

A.A. Mahmoud, A.A. Rahman, I.S. Mustafa, N.N.A Razak, N.Z. Yahaya, S. Kandaiya,

Background: An effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. Materials and Methods: The MAGAT gel dosimeter formulations that used different compositions of Methacrylic acid (MAA) and gelatin were extensively investigated in the present study according to the R2–dose response and R2–dose sensitivity. The irradiation of M...

2013
Guang Zhao Caili Dai Mingwei Zhao Qing You Ang Chen

A dispersed particle gel (DPG) was successfully prepared from a polymer gel at room temperature. The polymer gel system, morphology, viscosity changes, size distribution, and zeta potential of DPG particles were investigated. The results showed that zirconium gel systems with different strengths can be cross-linked within 2.5 h at low temperature. Scanning electron microscopy (SEM), transmissio...

Ahmad Mostaar, Mahmoud Shiri Seyed Mohsen Sadat-Shahabi Zahra Mansouri

Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...

Journal: :International Journal of Molecular Sciences 2008
Akira Kakugo Kazuhiro Shikinaka Jian Ping Gong

We present a soft bio-machine constructed from biological motors (actin/myosin). We have found that chemically cross-linked polymer-actin complex gel filaments can move on myosin coated surfaces with a velocity as high as that of native F-actin, by coupling to ATP hydrolysis. Additionally, it is shown that the velocity of polymer-actin complex gel depends on the species of polycations binding t...

2010
Sebastian Seiffert David A. Weitz

We fabricate thermo-responsive polymer microgels by combining microfluidic pre-gel emulsification with polymer-analogous gelation. This separates the microgel formation from the polymer synthesis; it combines highly controlled microfluidic templating with the great flexibility of preparative polymer chemistry, allowing each to be controlled independently. We produce monodisperse pre-gel droplet...

2003
J. Bergenholtz W. C. K. Poon M. Fuchs

Mode coupling theory (MCT) is used to model gel formation in mixtures of colloidal particles and nonadsorbing polymer. The polymer induces an effective, short-range attraction among the colloids, which is modeled by a depletion attraction of the Asakura-Oosawa form. This enables the MCT to be solved analytically for dilute systems, leading to a prediction, free of adjustable parameters, of the ...

2014
Weirong Li Jianlei Sun

Carbon dioxide has been used commercially to recover oil from reservoirs for more than 40 years. Currently, CO2 flooding is the second most applied enhanced oil recovery (EOR) process in the world behind steam flooding. Water alternating gas (WAG) injection has been a popular method to control mobility and improve volumetric sweep efficiency for CO2 flooding. Average EOR is about 9.7% with a ra...

Journal: :journal of biomedical physics and engineering 0
h khosravi tarbiat modares university b hashemi tarbiat modares university s r mahdavi irani university of medical sciences p hejazi semnan university of medical sciences

background: gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. objective: the ability of a new formulation of magic-f polymer gel was assessed by experimental measurement and monte carlo (mc) method for studying the effect of gold nanoparticles (gnps) in prostate dose distributions under the internal ir-192 and external 18mv radioth...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید