نتایج جستجو برای: power system harmonics
تعداد نتایج: 2587527 فیلتر نتایج به سال:
The traditional infrastructure of power system industry is presently going through large amount of change that consensus over the improvement of power quality for fulfilling this requirement electronically automated devices having high sensitivity toward the disturbance in the power system signals are under the major consensus of research activities. The low power quality signal is responsible ...
The design of ternary pseudo random maximum length signals suitable for system identification under noisy conditions is considered, where the power content in the specified harmonics should be high. Signal levels conversion for mapping a maximum length sequence in the Galois field into three signal levels is proposed such that the primitive version of the signal has only one nonzero harmonic at...
This paper deals with an indirect current controlled shunt active power filter (SAPF) for improving power quality by reactive power compensation and harmonic filtering. The presence of harmonics and reactive power in the power source because it will cause additional power losses and malfunctions. The proposed APF is based on a voltage source inverter (VSI). The VSI is controlled by two loops, t...
The flicker and harmonics generated by electric arc furnaces present a problem that is well known to both the steel industry and electrical utilities. This paper presents a method to compensate for measurement errors introduced by current and voltage transformers and anti-aliasing filters in a power quality measurement system. Dynamic compensation may be performed in real time using digital fil...
The nonlinear load such as UPS, fan controller, mobile charger is distorting the supply current waveform. This current harmonics derates the power system equipment. To avoid this current harmonics, filters namely passive filter / active filter /hybrid filters are introduced in the supply line. In this paper the overall view of the performance of the various filters are studied and the performan...
BACKGROUND The aim of the present study was to assess the clinical significance of spectral analysis of plethysmographic waveform in patients with coronary artery disease (CAD) and after coronary artery bypass graft (CABG) surgery. METHODS AND RESULTS The study group comprised 26 healthy subjects, 15 CAD patients, and 24 CAD patients after CABG. Finger plethysmographic waveforms from both rig...
Shunt capacitors installation in distribution systems requires optimal placement and sizing. More harmonics are being injected into distribution systems. Adding shunt capacitors may lead to high distortion levels. The capacitor placement and sizing problem is a nonlinear integer optimization problem, with locations and ratings of shunt capacitors being discrete values. The goal is to minimize t...
In India, the electric power transmission and distribution loss is very high, about 7% in transmission and 26% in distribution. Though deployment of automated meter reading system will reduce losses, particularly in distribution, penetration of automated meter reading is low due to high costs involved. World over, the Two-Way Automatic Communications System (TWACS) is the most widely used power...
AbstractThis paper presents an investigation of five-Level Cascaded H – bridge (CHB) Inverter as Distribution Static Compensator (DSTATCOM) in Power System (PS) for compensation of reactive power and harmonics. The advantages of CHB inverter are low harmonic distortion, reduced number of switches and suppression of switching losses. The DSTATCOM helps to improve the power factor and eliminate t...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید