نتایج جستجو برای: pump

تعداد نتایج: 63050  

Journal: :General thoracic and cardiovascular surgery 2007
Kenji Yamazaki Satoshi Saito Shinichiro Kihara Osamu Tagusari Hiromi Kurosawa

OBJECTIVE Various types of rotary blood pumps (axial flow, centrifugal) have been introduced into clinical use recently. These pumps have different pressure-flow characteristics, and some investigators have noted that a limited pump flow rate and less pulsatility are the problems with the axial flow devices. METHODS A new implantable centrifugal blood pump was developed that has an extremely ...

Journal: :European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery 2016
Ashima Singh Hartzell V Schaff Maria Mori Brooks Mark A Hlatky Stephen R Wisniewski Robert L Frye Edward Y Sako

OBJECTIVES Conclusive evidence is lacking regarding the benefits and risks of performing off-pump versus on-pump coronary artery bypass graft (CABG) for patients with diabetes. This study aims to compare clinical outcomes after off-pump and on-pump procedures for patients with diabetes. METHODS The Bypass Angioplasty Revascularization Investigation 2 Diabetes (BARI 2D) trial enrolled patients...

Journal: :Journal of diabetes science and technology 2009
David C Klonoff Juliet S Reyes

Diabetes Technology Society convened a panel of insulin pump experts in Bethesda, Maryland, on November 12, 2008, at the request of the Food and Drug Administration. The group consisted of physicians, nurses, diabetes educators, and engineers from across the United States. The panel members (1) discussed safety features of insulin pump therapy and (2) recommended adjustments to current insulin ...

Journal: :Applied optics 2015
Karsten Schuhmann Theodor W Hänsch Klaus Kirch Andreas Knecht Franz Kottmann Francois Nez Randolf Pohl David Taqqu Aldo Antognini

Thin-disk laser pump layouts yielding an increased number of passes for a given pump module size and pump source quality are proposed. These layouts result from a general scheme based on merging two simpler pump optics arrangements. Some peculiar examples can be realized by adapting standard, commercially available pump optics with an additional mirror pair. More pump passes yield better effici...

2009
Shane W. Butler John V. Ringwood Niall MacGearailt

This paper addresses the issue of vacuum pump degradation in semiconductor manufacturing. The ability to identify the current level of vacuum pump degradation and predict the Remaining-Useful-Life (RUL) of a dry vacuum pump would allow manufacturers to schedule pump swaps at convenient times, and reduce the instances of unexpected pump failures, which can incur significant costs. In this paper,...

Journal: :Journal of Ayub Medical College, Abbottabad : JAMC 2008
Imran Hussain Abdul Ghaffar Ahmad Shahbaz Waqas Sami Amina Muhammad Nadia Seher Fazal Wahab Jawad Sajid Khan

BACKGROUND Due to advancement of non-surgical methods of coronary revascularization the patients referred for surgery have extensive and complex coronary anatomy. Patients with diffuse atheromatous coronary artery disease required coronary artery reconstruction or coronary endarterectomy (CE). Coronary endarterectomy on beating heart needs skill and better surgical technique. Coronary endartere...

Journal: :The Medical journal of Malaysia 2011
H L Ooi L L Wu

Hospital UKM (Universiti Kebangsaan Malaysia) introduced the use of insulin pump therapy in children and adolescents with Type 1 Diabetes in Malaysia in April 2004. This study aims to evaluate the effectiveness of pump therapy and its impact on metabolic control among patients from our institution. Insulin pump therapy resulted in sustainable improvement in glycemic control throughout the six y...

2010
K. X. Qian T. Jing L. Li

AbstractThe comfortability of the receiptor with a left ventricular assist pump becomes more and more important along with the daily prolonged survival. Thereby it is necessary to achieve automatic measurement and bionic control for heart pump. The key-point is to improve the sensitivity of flow rate change after the pressure head variation in the pump, so as to maintain the flow rate balance b...

Journal: :The Journal of biological chemistry 2016
Takatoshi Hasemi Takashi Kikukawa Naoki Kamo Makoto Demura

Light-driven ion-pumping rhodopsins are widely distributed in microorganisms and are now classified into the categories of outward H(+) and Na(+) pumps and an inward Cl(-) pump. These different types share a common protein architecture and utilize the photoisomerization of the same chromophore, retinal, to evoke photoreactions. Despite these similarities, successful pump-to-pump conversion had ...

Journal: :The journal of extra-corporeal technology 2003
Wolfgang Boettcher Frank Merkle Heinz-Hermann Weitkemper

The first roller pump was patented in 1855 by Porter and Bradley and was hand operated. A modification first named "surgical pump", designed and manufactured by E. E. Allen in 1887, was intended for direct blood transfusion. Truax, who also distributed and promoted the Allen pump with one roller, developed the first double roller pump in 1899. In the following decades, several researchers, incl...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید